FIRE-RETARDANT COMMUNICATION CABLES FOR
COAL MINES(Signal electric cable)
产品用途:产品适用于煤矿井下监测、控制系统作低频信号传输线。
Scope of
application:The product is suitable for the coal mine mine shaft monitor
the control system makes the low-frequency ** transmission line
执行标准 Standards
implemented: Q/3210HL07-2005
|
|
型号名称及使用范围 Model descriptions and Use
scope
型 号
Model
|
名 称
Descriptions
|
使 用 范 围
Use scope
|
MHYV(PUYV)
|
煤矿用聚乙烯绝缘聚氯乙烯护套通信电缆
PE insulated PVC sheathed communication cables for coal mine
|
用于井下平巷、斜巷及机电硐室作普通信号传输
Used in level; or slanted channels and power house
|
MHYVR(PUYVR)
|
煤矿用聚乙烯绝缘聚氯乙烯护套通信电缆
PE insulated PVC sheathed communication cables for coal mine
|
用于井下平巷、斜巷及机电硐室作普通信号传输
Used in level; or slanted channels and power house
|
MHYVP(PUYVP)
|
煤矿用聚乙烯绝缘铜丝编织屏蔽聚氯乙烯护套通信电缆
PE insulated copper wire weave shielded PVC sheathed communication cables
|
用于井下干扰较大的场合作信号传输
Served in coal mine where interference is strong
|
MHYVRP(PUYVRP)
|
煤矿用聚乙烯绝缘聚氯乙烯护套铜丝编织屏蔽通信软电缆
PE insulated copper wire weave shielded PVC sheathed communication soft
cables
|
用于井下干扰较大的场合作信号传输
Served in coal mine where interference is strong
|
MHYBV(PUYV31)
|
煤矿用聚乙烯绝缘镀锌钢丝编织铠装聚氯乙烯护套通信电缆
PE insulated tinned steel wire weave armored PVC sheathed communication
cables
|
用于井下平巷或斜巷作主信号传输能承受一定的机械冲击力
Served in level and slanted channels where the mechanic impact is strong
|
MHY32
(PUYV39、39-1)
|
煤矿用聚乙烯绝缘聚氯乙烯护套钢丝铠装通信电缆
PE insulated steel wire armored PVC sheathed communication cables
|
用于竖井或斜井作主信号传输能承受较大的拉力
Served as major ** line in shaft or slanted shaft in coal minescapable
of being under considerable pull force
|
使用特性 Service characteristics
电缆长期允许工作温度
Long-term service temperature of the cable conductor
|
70℃
|
电缆敷设温度 Cable laying temperature
|
≥0℃
|
+25℃时环境相对湿度 Environment relative
humidity at 25℃
|
≤95%
|
电缆的传输频率 Transmission frequency of cable
|
≤30KHz
|
电缆的较小弯曲半径 Minimun bending radius
|
MHYVR及MHYVRP型电缆为电缆外径的10倍,其它型号为外径的15倍
10 times of the cable outer diameter of MHJYV and 15times for the rest
|
电缆结构示意图
IIIustration of cable structure
电缆规格 Specifications
型 号
Model
|
标准截面 Nominal sectional area(mm2)
|
0.5
|
0.75
|
0.8
1.0
|
1.5
|
0.5
|
0.75
|
0.8
|
1.0
|
1.5 0.5
|
0.75
|
0.8
|
1.0
|
1.5
|
-
|
芯 数Core No.
|
对 数Pair No.
|
导体结构Conductor structure
|
MHYV
|
2-7
|
2-10
|
1/0.8
7/0.30
|
1/0.97
7/0.37
|
-
|
1/1.13
7/0.43
|
1/1.38
7/0.52
|
MHYVR
|
2-7
|
2-10
|
-
|
42/0.15
|
-
|
32/0.20
|
48/0.20
|
MHYVP
|
2-7
|
2-10
|
1/0.8
7/0.30
|
1/0.97
7/0.37
|
-
|
1/1.13
7/0.43
|
1/1.38
7/0.52
|
MHYVRP
|
2-7
|
2-10
|
-
|
42/0.15
|
-
|
32/0.20
|
48/0.20
|
MHYBV
|
2-7
|
2-10
|
-
|
1/0.97
7/0.37
42/0.15
|
1/1.0
|
1/1.13
7/0.43
32/0.20
|
1/1.38
7/0.52
48/0.20
|
MHY32
|
-
|
3-7
|
2-19
|
-
|
1/0.97
7/0.37
|
-
|
1/1.13
7/0.43
|
1/1.38
7/0.52
|
电缆主要技术性能 Major
technical performances
1、电缆导体直流电阻和电缆固有衰减 DC resistance of the
conductor and Intrinsic attenuation
型 号 Model
|
标称截面
Nominal sectional area
mm2
|
导 体 结 构 Conductor structure
|
20℃时导体直流电阻
DC resistance of the conductor at 20℃
(≤Ω/Km)
|
固有衰减 Intrinsic attenuation
(800Hz) (≤dB/Km)
|
种 类 Type
|
根数/单线标称直径 PC.No./Single track diameter(mm)
|
MHYV
MHYVR
MHYVRP
MHYVP
MHYBV
MHY32
|
0.5
|
1
|
1/0.8
|
36.0
|
1.0
|
2
|
7/0.30
|
36.0
|
0.75
|
1
|
1/0.97
|
24.5
|
0.8
|
2
|
7/0.37
|
24.5
|
6
|
42/0.15
|
26.0
|
0.8
|
1
|
1/1.0
|
25.8
|
0.7
|
1.0
|
1
|
1/1.13
|
18.1
|
0.65
|
2
|
7/0.43
|
18.1
|
5
|
32/0.20
|
19.5
|
1.5
|
1
|
1/1.38
|
12.1
|
0.5
|
2
|
7/0.52
|
12.1
|
5
|
48/0.20
|
13.3
|
2、电缆其它主要技术性能 Other major technical
performances
(型号 Model:MHYV、MHYVR、MHYVRP、MHYVP、MHYBV、MHY32)
序 号
Serial number
|
项目Items
|
技术性能
Technical performances
|
1
|
+20℃线芯导体直流电阻(≤Ω/Km) Line core DC
resistance at 20℃
|
见上表 See above table
|
2
|
电缆固有衰减(≤dB/Km) Cable intrinsic attenuation
|
见上表 See above table
|
3
|
+20℃绝缘电阻(≥MΩ Km) Insulating resistance
at 20℃
|
5000
|
4
|
lmin工频交流电压试验
lmin power frequency alternating current pressure test
|
芯-芯
Core - core
芯-屏蔽
Core - hield
|
1500V不击穿(50Hz)
1500V Does not penetrate
|
5
|
电缆工作电容(≤μF/Km) Cable service capacity
|
0.06(800Hz)
|
6
|
远端串音衰减(≥dB/500) Far-end crosstalk attenuation
|
70(800Hz)
|
7
|
电感(≤μH/Km) Inductance
|
800(800Hz)
|
8
|
工作对直流电阻差(≤%环阻) DC resistance difference
|
2
|
9
|
单根垂直燃烧试验 Combustion for single cable test
|
MT386
|
10
|
成束燃烧试验 Combustion for bunched cable test
|
符合GB/T18380标准中B类成束燃烧试验要求
Conforms to GB/T18380 standard B kind becomes ties the burning test
|
|
|
|
|
|