KCD2-ST-Ex1.LB Switch Amplifier 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-STC-Ex1.SP SMART Transmitter Power Supply 1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-SON-Ex1.R1 Switch Amplifier 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive), Application-specific outputs, Line fault transparency (LFT), Usable as ** splitter (1 input and 2 outputs), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD0-LGH.SP Place Holder Barrier IS K-System place holder module, Housing width 12.5 mm, Marshalling for field and control side circuits, Configurable via plug-in jumpers, Connection via spring terminals with push-in connection technology KCD2-RR2-Ex1.SP Resistance Repeater 1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the control system KCD2-SON-Ex1.SP Switch Amplifier 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-SON-Ex2.SP Switch Amplifier 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-SOT-1.LB.SP Switch Amplifier 1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-SOT-2.SP Switch Amplifier 2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-SOT-Ex1.LB.SP Switch Amplifier 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-SR-2.SP Switch Amplifier 2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-ST-1.LB.SP Switch Amplifier 1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-ST-2.SP Switch Amplifier 2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-ST-Ex1.LB.SP Switch Amplifier 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-ST-Ex2.SP Switch Amplifier 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-STC-Ex1.2O.DE SMART Transmitter Power Supply 1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508 KCD2-STC-Ex1.ES.SP SMART Transmitter Power Supply 1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 3 acc. to IEC 61508 KCD0-SD-Ex1.1245 Solenoid Driver 1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508 KCD2-STC-1 SMART Transmitter Power Supply 1-channel ** conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD0-SD-Ex1.1245.SP Solenoid Driver 1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 3 acc. to IEC 61508 KCD2-RR-Ex1-Y1 Resistance Repeater 1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the control system KCD2-RR-Ex1.SP Resistance Repeater 1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the control system KCD2-SLD-Ex1.1045 Solenoid Driver 1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508 KCD2-SLD-Ex1.1065 Solenoid Driver 1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 65 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508 KCD2-SLD-Ex1.1245 Solenoid Driver 1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508 KCD2-STC-1.SP SMART Transmitter Power Supply 1-channel ** conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-SCD-1 SMART Current Driver 1-channel ** conditioner, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.1 %, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field KCD2-SCD-1.SP SMART Current Driver 1-channel ** conditioner, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.1 %, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
词条
词条说明
HCD2-FBPS-1.23.500 现场总线电源集线器,紧凑型电源模块 输出:21 ... 23 V / 500 mA,实体ic和Ex nL的电压限制,带电隔离,安装在区域2 / I类,分区。 2,用于基金会现场总线H1和PROFIBUS PA HCD2-FBPS-1.500 现场总线电源集线器,紧凑型电源模块 输出:28 ... 30 V / 500 mA,高功率干线,用于增加设备数量和延长电
396R-10-21-54rosemount pH传感器 396P-01- -11-54Rosemount pH电 396P-01- -10-54Rosemount pH电 396P-02-10-54Rosemount pH电 396P-02-11-54Rosemount pH电 396P-02-11-55Rosemount pH电 396P-02-12-55Rosemount 0RP电
Rosemount? 398RVP 可伸缩式 pH/ORP 传感器
Rosemount™ 3500P PERpH-X™ pH/ORP 传感器 Rosemount™ 398RVP 可伸缩式 pH/ORP 传感器 rosemount 3400ht and 3400htvp sensor Rosemount™ 3400HTVP PERpH-X™ pH/ORP Retractable Sensor rosemount 3400ht and 3400htvp sensor
SGM7G SGM7G-13D7FKH 编码器类型 ** 额定输出 1.3千瓦 可以选择的 SGM7G SGM7G-05A6A6C 编码器类型 无电池** 额定输出 0.45千瓦 可以选择的 SGM7G SGM7G-44D7F6H 编码器类型 ** 额定输出 4.4千瓦 可以选择的 SGM7G SGM7G-05A6A61 编码器类型 无电池** 额定输出 0.45千瓦 SGM7G SGM7G-30AFA2S
公司名: 上海创弗实业有限公司
联系人: 张晓龙
电 话: 18001664790
手 机: 18001664790
微 信: 18001664790
地 址: 上海松江方松辰塔路2号
邮 编: