KCD0-SD-Ex1.1245.SP倍加福

    KCD2-ST-Ex1.LB
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
    
    KCD2-STC-Ex1.SP
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
    
    KCD2-SON-Ex1.R1
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive), Application-specific outputs, Line fault transparency (LFT), Usable as ** splitter (1 input and 2 outputs), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
    
    KCD0-LGH.SP
    Place Holder Barrier
    IS K-System place holder module, Housing width 12.5 mm, Marshalling for field and control side circuits, Configurable via plug-in jumpers, Connection via spring terminals with push-in connection technology
    
    KCD2-RR2-Ex1.SP
    Resistance Repeater
    1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the control system
    
    KCD2-SON-Ex1.SP
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
    
    KCD2-SON-Ex2.SP
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
    
    KCD2-SOT-1.LB.SP
    Switch Amplifier
    1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
    
    KCD2-SOT-2.SP
    Switch Amplifier
    2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
    
    KCD2-SOT-Ex1.LB.SP
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
    
    KCD2-SR-2.SP
    Switch Amplifier
    2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
    
    KCD2-ST-1.LB.SP
    Switch Amplifier
    1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
    
    KCD2-ST-2.SP
    Switch Amplifier
    2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
    
    KCD2-ST-Ex1.LB.SP
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
    
    KCD2-ST-Ex2.SP
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
    
    KCD2-STC-Ex1.2O.DE
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508
    
    KCD2-STC-Ex1.ES.SP
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 3 acc. to IEC 61508
    
    KCD0-SD-Ex1.1245
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508
    
    KCD2-STC-1
    SMART Transmitter Power Supply
    1-channel ** conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
    
    KCD0-SD-Ex1.1245.SP
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 3 acc. to IEC 61508
    
    KCD2-RR-Ex1-Y1
    Resistance Repeater
    1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the control system
    
    KCD2-RR-Ex1.SP
    Resistance Repeater
    1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the control system
    
    KCD2-SLD-Ex1.1045
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508
    
    KCD2-SLD-Ex1.1065
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 65 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508
    
    KCD2-SLD-Ex1.1245
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508
    
    KCD2-STC-1.SP
    SMART Transmitter Power Supply
    1-channel ** conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
    
    KCD2-SCD-1
    SMART Current Driver
    1-channel ** conditioner, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.1 %, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KCD2-SCD-1.SP
    SMART Current Driver
    1-channel ** conditioner, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.1 %, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field

    上海创弗实业有限公司专注于安川伺服电机,罗斯蒙特变送器罗斯蒙特分析仪,库伯勒编码器等

  • 词条

    词条说明

  • 396-54-62,396VP-54

    396:TUpH 浸没式/插入式 pH/ORP 不锈钢传感器罗斯蒙特分析仪396-54-62,396VP-54 396-54:54、54e、1054A、1054B、1055、1056、1057 和 1066;系列:81、2081、3081、4081、5081、6081、XMT (PT100 RTD) 396-54-62:54、56、1055、1056、1057、1066、81、1181、2081、

  • 罗斯蒙特398/398VP/398R/398RVPTUpH?pH/ ORP传感器

    Rosemount™ 398RVP 可伸缩式 pH/ORP 传感器 罗斯蒙特398 / 398VP / 398R /398RVPTUpH®pH/ ORP传感器 罗斯蒙特398/398VP/398R/398RVPTUpH®pH/ ORP传感器 Rosemount 398RVP 采用 Tefzel™ 和钛质抗化学腐蚀结构、以及取得**的 TUpH™ 参比液接,使之成为测量苛刻过程液体 pH 值的理想传

  • CLV620-2000S01固定式条形码扫描器

    CLV620-2000S01订货号: 1064461产品系列: CLV62x产品系列: 识别解决方案, 固定式条形码扫描器 光学聚焦: 固定焦距 连接电缆 阅读领域: 侧面 (105°) 扫描设计: 行扫描 外壳防护等级: IP65 前镜: 玻璃 CLV620-0000 CLV620-0000订货号: 1040288产品系列: CLV62x产品系列: 识别解决方案, 固定式条形码扫描器 光学聚焦:

  • 罗斯蒙特396/396P/396R传感器 pH/ORP

    罗斯蒙特396/396P/396R传感器 pH/ORP 罗斯蒙特396/396P/396R传感器 pH/ORP型号:TUpH™ 396/396P/396R 可抽取式/浸入式/插入式-pH/ORP 传感器 ⋅ SILCORE™2三重密封技术-提高传感器在高温工况下的使用寿命; ⋅ 工作压力高-三种型号传感器,在 100°C(212°F)条件下,大工作压力为 150psig(1136KPa 绝压);

联系方式 联系我时,请告知来自八方资源网!

公司名: 上海创弗实业有限公司

联系人: 张晓龙

电 话: 18001664790

手 机: 18001664790

微 信: 18001664790

地 址: 上海松江方松辰塔路2号

邮 编:

网 址: chuangfusy.b2b168.com

八方资源网提醒您:
1、本信息由八方资源网用户发布,八方资源网不介入任何交易过程,请自行甄别其真实性及合法性;
2、跟进信息之前,请仔细核验对方资质,所有预付定金或付款至个人账户的行为,均存在诈骗风险,请提高警惕!
    联系方式

公司名: 上海创弗实业有限公司

联系人: 张晓龙

手 机: 18001664790

电 话: 18001664790

地 址: 上海松江方松辰塔路2号

邮 编:

网 址: chuangfusy.b2b168.com