KFD2-HLC-Ex1.D倍加福KFD2-SOT3-Ex1.LB

    KFD0-HMS-16
    HART Multiplexer Slave
    16-channel, No external power required, HART field device input (revision 5 to 7), Used with HART Multiplexer Master KFD2-HMM-16, Up to SIL 3 acc. to IEC 61508
    
    KFD0-RO-Ex2
    Relay Module
    2-channel isolated barrier, 24 V DC supply (loop powered), Logic input 15 V DC ... 30 V DC, non-polarized, Relay contact output, Up to SIL 3 acc. to IEC 61508
    
    KFD0-SCS-Ex1.55
    SMART Current Driver/Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex protection, Transfer direction: to the field / to the control system
    
    KFD0-SD2-Ex2.1045
    Solenoid Driver
    2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD2-CRG2-Ex1.D
    Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-EB2.R4A.B
    Redundant Power Feed Module
    Interface for Power Rail, Used for redundant configuration, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication
    
    KFD2-GUT-Ex1.D
    Temperature Converter with Trip Values
    1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-HMM-16
    HART Multiplexer Master
    16-channel, 24 V DC supply (Power Rail), HART field device input (revision 5 to 7), Up to 15 KFD0-HMS-16 slave units can be connected, Up to SIL 3 acc. to IEC 61508
    
    KFD2-SCD2-Ex1.LK
    SMART Current Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-SCD2-Ex2.LK
    SMART Current Driver
    2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-SL2-Ex2.B
    Solenoid Driver
    2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SOT3-Ex1.LB
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SOT3-Ex2
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC5-1
    SMART Transmitter Power Supply
    1-channel ** conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC5-1.2O
    SMART Transmitter Power Supply
    1-channel ** conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink/current source, Terminals with test points, Up to SIL 3 acc. to IEC 61508
    
    KFD2-STC5-Ex1
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC5-Ex1.2O
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink/current source, Terminals with test points, Up to SIL 3 acc. to IEC 61508
    
    KFD2-STC5-Ex2
    SMART Transmitter Power Supply
    2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-UFC-Ex1.D
    Frequency Converter with Trip Values
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input for NAMUR sensors or dry contacts, Input frequency 1 mHz ... 5 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-USC-1.D
    Signal Converter with Trip Value
    1-channel ** conditioner, 24 V DC supply (Power Rail), Scaleable current or voltage input, Current or voltage output, Relay contact output, Configurable by keypad, Line fault detection (LFD)
    
    KFD2-UT2-Ex1
    Universal Temperature Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-UT2-Ex2
    Universal Temperature Converter
    2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as ** splitter (1 input and 2 outputs), Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-VR4-Ex1.26
    Voltage Repeater
    1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... -20 V, Vibration sensor inputs, Voltage/current field supply, Voltage output 0 V ... -20 V, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the control system
    
    KFD0-CC-1
    Current/Voltage Converter
    1-channel ** conditioner, 24 V DC supply (loop powered), Current or voltage input, Output: 4 ... 20 mA, Potentiometer or DIP switch selectable ranges, Line fault detection (LFD)
    
    KFD0-CC-Ex1
    Current/Voltage Converter
    1-channel isolated barrier, 24 V DC supply (loop powered), Current or voltage input, Output: 4 ... 20 mA, Potentiometer or DIP switch selectable ranges, Line fault detection (LFD)
    
    KFD0-CS-Ex1.50P
    Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
    
    KFD0-CS-Ex1.51P
    Current Driver/Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
    
    KFD0-CS-Ex1.54
    Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Up to SIL 3 acc. to IEC 61508, Transfer direction: to the control system
    
    KFD0-CS-Ex2.51P
    Current Driver/Repeater
    2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
    
    KFD0-RSH-1.4S.PS2
    Relay Module
    1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 20 V DC ... 26.5 V DC, non-polarized, Fail-safe relay contact output for de-energized and energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508
    
    KFD0-SCS-1.55
    SMART Current Driver/Repeater
    1-channel ** conditioner, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
    
    KFD0-SD2-Ex1.10100
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 100 mA at 10 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD0-SD2-Ex1.1180
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 80 mA at 11 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD0-SD2-Ex2.1245
    Solenoid Driver
    2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD0-TR-1
    RTD Converter
    1-channel ** conditioner, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA ... 20 mA, temperature linearization selectable, DIP switch selectable ranges, Sensor breakage detection
    
    KFD0-TR-Ex1
    RTD Converter
    1-channel isolated barrier, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA ... 20 mA, temperature linearization selectable, DIP switch selectable ranges, Sensor breakage detection
    
    KFD2-BR-1.PA.1500
    Basic Segment Coupler
    Output: 24 ... 26 V/400 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, Up to 1.5 MBit auto-adapting
    
    KFD2-CD-1.32
    Current Driver
    1-channel ** conditioner, 24 V DC supply (Power Rail), Current input 0 mA ... 20 mA, Current output 0 mA ... 20 mA, Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-CRG2-1.D
    Transmitter Power Supply
    1-channel ** conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-DWB-1.D
    Rotation Speed Monitor
    1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 12 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-DWB-Ex1.D
    Rotation Speed Monitor
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 5 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-EB2
    Power Feed Module
    Interface for Power Rail, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication
    
    KFD2-ER-1.6
    Conductivity Switch Amplifier
    1-channel ** conditioner, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 5 kΩ ... 150 kΩ, Relay contact output, Minimum/maximum control
    
    KFD2-ER-Ex1.W.LB
    Conductivity Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Relay contact output, Fault relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD)
    
    KFD2-GS-1.2W
    Current/Voltage Trip Value
    1-channel ** conditioner, 24 V DC supply (Power Rail), Current and voltage input, 2 relay contact outputs, Programmable high/low alarm, Configurable via DIP switches and potentiometer, Terminal blocks with test sockets
    
    KFD2-GUT-1.D
    Temperature Converter with Trip Values
    1-channel ** conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-HLC-Ex1.D
    HART Loop Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as ** splitter (1 input and several outputs), 3 analog outputs 4 mA ... 20 mA, Sink and source mode output, Configurable by keypad
    
    KFD2-PT2-Ex1
    Potentiometer Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 10 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508
    
    KFD2-PT2-Ex1-5
    Potentiometer Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 4 mA ... 20 mA, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508
    
    KFD2-RCI-Ex1
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Output 20.4 mA at 13.5 V DC, 19 V DC ... 30 V DC input, Line fault detection (LFD), Conformal coating, Up to SIL 3 acc. to IEC 61508

    上海创弗实业有限公司专注于安川伺服电机,罗斯蒙特变送器罗斯蒙特分析仪,库伯勒编码器等

  • 词条

    词条说明

  • 389-01-10-54罗斯蒙特分析仪

    389:三重液接 pH/ORP 传感器罗斯蒙特分析仪 389-01-10-50:智能前置放大器,25' 电缆,GPLR,兼容 1181/1050/1060 389-01-10-54:智能前置放大器,GPLR,1054A/B/81/2081;兼容 54/56/1055/1056/1057/1066/5081/6081/XMT 389-01-10-55:智能前置放大器,25' 电缆,GPLR,兼容 5

  • 探头\396R-10-21-54-60

    探头\396R-10-21-54-60 Rosemount™ 56 双通道变送器 Rosemount 56 双通道变送器是一种线路供电设备,可接收 pH/ORP 传感器、ISE、流量、电流、传导率传感器(接触和环形)传感器、浊度传感器和安培(溶解氧、氯和臭氧传感器)传感器的输入 认证 FM:I 类,2 分类,A、B、C 和 D 组 • Il 和 III 类,2 分类,E、F 和 G 组 • T4

  • KFD2-SR3-2.2S倍加福KCD2-SR-1.LB

    KCD2-SR-1.LB KFD2-SR3-2.2S倍加福KCD2-SR-1.LB Switch Amplifier 1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), Re

  • 396PVP-10-55-41

    罗斯蒙特分析仪396PVP:TUpH 浸没式/插入式 pH/ORP 传感器(VP 接头)罗斯蒙特分析仪 396PVP-10-55:GPLR,兼容 54/56/1055/1056/1057/81/3081/4081/5081/6081/XMT,VP 接头 396PVP-10-55-41:GPLR,兼容 54/56/1055/1056/1057/81/3081/4081/5081/6081/XMT,V

联系方式 联系我时,请告知来自八方资源网!

公司名: 上海创弗实业有限公司

联系人: 张晓龙

电 话: 18001664790

手 机: 18001664790

微 信: 18001664790

地 址: 上海松江方松辰塔路2号

邮 编:

网 址: chuangfusy.b2b168.com

八方资源网提醒您:
1、本信息由八方资源网用户发布,八方资源网不介入任何交易过程,请自行甄别其真实性及合法性;
2、跟进信息之前,请仔细核验对方资质,所有预付定金或付款至个人账户的行为,均存在诈骗风险,请提高警惕!
    联系方式

公司名: 上海创弗实业有限公司

联系人: 张晓龙

手 机: 18001664790

电 话: 18001664790

地 址: 上海松江方松辰塔路2号

邮 编:

网 址: chuangfusy.b2b168.com

    相关企业
    商家产品系列
  • 产品推荐
  • 资讯推荐
关于八方 | 八方币 | 招商合作 | 网站地图 | 免费注册 | 一元广告 | 友情链接 | 联系我们 | 八方业务| 汇款方式 | 商务洽谈室 | 投诉举报
粤ICP备10089450号-8 - 经营许可证编号:粤B2-20130562 软件企业认定:深R-2013-2017 软件产品登记:深DGY-2013-3594
著作权登记:2013SR134025