RD0-TI-Ex8.PA.*

    HCD2-FBPS-1.23.500
    Fieldbus Power Hub, Compact Power Supply Module
    
    Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HCD2-FBPS-1.500
    Fieldbus Power Hub, Compact Power Supply Module
    
    Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-DM-A
    Fieldbus Power Hub, Advanced Diagnostic Module
    
    Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-GTR-4PA
    PROFIBUS Power Hub, Gateway Module
    
    PROFIBUS DP V1 / For 4 segments PA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Optional redundant configuration, Installation in Zone 2/Class I, Div. 2, Up to 12 Mbit/s, auto adapting
    
    KT-MB-GT2AD.FF
    Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface
    
    System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PA
    
    R-SP-E12
    Segment Protector for Cabinet Installation
    
    Segment Protector for Cabinet Installation, 12 increased safety outputs (Ex e), Short circuit current limitation per output, Segment Protector in Zone 1/Div. 2, Instruments in Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    ELS-1
    Enclosure Leakage Sensor
    Housing leakage sensor, for operation with FOUNDATION Fieldbus and PROFIBUS PA, Indication via LED and Advanced Diagnostics, Intrinsically safe, FISCO or Entity, For instrument or device coupler, Fits inside terminal compartment, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-DM-B
    Fieldbus Power Hub, Basic Diagnostic Module
    Basic monitoring for power supply output and health, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    KFD2-BR-1.PA.1500
    Basic Segment Coupler
    Output: 24 ... 26 V/400 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, Up to 1.5 MBit auto-adapting
    
    KLD0-SAA
    Voltage adjustment module
    Series voltage reducing module, Removable terminals, Polarity reversal protected, Installation in cabinet on DIN mounting rail, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    KLD2-FBPS-1.25.360
    Fieldbus Power Supply
    Output: 25 ... 27 V/360 mA, For most fieldbus applications, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1
    
    BP-FBPS-1.30.1
    Portable Fieldbus Battery
    Portable Fieldbus Battery, Adjustable output 15 ... 30 V/max.1 A , 8 hours operation at 500 mA without recharging, IP 54 - Rain and splash proof, Rugged housing for outdoor use, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    EI-0D2-10Y-10B
    Intrinsically safe Ethernet Isolator
    Galvanic Isolation I.S. to non-I.S. Port, 10/100 MBit/s according to IEEE 802.3/.3u, Installation in Zone 2, Ethernet in Zone 1 or Zone 0, Standard Ethernet patch or crossover cable, DIN-Rail mounted and OEM Version
    
    FBTA-228-BPFB-R-8R
    Compact Fieldbus Power Hub Motherboard for Invensys FBM 228
    8 segments, redundant, individual modules per segment, Customized for Invensys, FBM228, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    FDH-1
    Fieldbus Diagnostic Handheld
    Fieldbus Diagnostic Handheld, Comprehensive diagnostics for the fieldbus physical layer, Handheld with display and integrated expert system, Fieldbus interface Ex ia, FISCO, Entity, and DART, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-DM-A.RO
    Fieldbus Power Hub, Advanced Diagnostic Module with Relay Output
    Diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-GTR-4PA.PN
    PROFINET Power Hub, Gateway Module
    Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnostics
    
    KFD2-BR-Ex1.3PA.93
    Segment Coupler 1
    Output: 12.6 ... 13.4 V/100 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Intrinsically safe, Ex ia (FISCO or Entity), Installation in Zone 2/Class I, Div. 2, Fixed, high-availability terminator
    
    KLD2-FBPS-1.12.220
    Fieldbus Power Supply
    Output: 12 ... 13 V/220 mA, For battery or solar-powered applications, For demanding environmental conditions , Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1
    
    KLD2-PR-1.IEC
    Fieldbus Power Repeater
    Output: 24 ... 26 V/400 mA, For extension of fieldbus segments, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    KT-MB-DMA
    Advanced Diagnostic Module, Kit for Stand-Alone Operation
    Comprehensive diagnostics for the fieldbus physical layer, Module and motherboard for retrofit of any installation, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    KT-MB-GT2AD.FF.IO
    Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O
    System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Alarm handling and integrated I/O for cabinet monitoring/control, For FOUNDATION Fieldbus and PROFIBUS PA
    
    KT-SRT-FF
    Starter Kit for FOUNDATION Fieldbus H1 Infrastructure
    Starter Kit for FOUNDATION Fieldbus H1 Infrastructure, Complete hardware for connection of FOUNDATION Fieldbus H1 field devices to the host system of your choice, Output: 25 ... 28 V/360 mA, Connection of 6 field devices with individual short-circuit protection, High-power trunk for high device count and long cable lengths
    
    KT-SRT-PA
    Starter Kit for PROFIBUS PA Infrastructure
    Starter Kit for PROFIBUS PA Infrastructure, Complete hardware for connection of PROFIBUS PA field devices to a DP-Master, Output: 24 ... 26 V/400 mA, Connection of 6 field devices with individual short-circuit protection, High-power trunk for high device count and long cable lengths
    
    MBHC-FB-4R.YO.R
    Compact Fieldbus Power Hub Motherboard for Yokogawa ALF111
    Compact redundant Fieldbus Power Hub motherboard with redundant terminals for Yokogawa ALF111 on the right-hand side
    
    USB-FBPS-1.11.45.NI
    USB Fieldbus Power Supply
    USB Fieldbus Power Supply, Output: min. 11 V/45 mA, For 1...2 devices/test setups, In conjunction with NI PCMCIA-FBUS card, Permitted for Zone 2 operation, For FOUNDATION Fieldbus H1
    
    HD2-FBPS-1.500
    Fieldbus Power Hub, Power Supply Module
    Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-FBPS-1.17.500
    Fieldbus Power Hub, Power Supply Module
    Output: 15 ... 17 V/500 mA, Voltage limitation for FISCO ic, Entity ic, also FNICO and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-FBPS-1.23.500
    Fieldbus Power Hub, Power Supply Module
    Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-FBPS-1.25.360
    Fieldbus Power Hub, Power Supply Module
    Output: 25 ... 28 V/360 mA, Universal power supply for most applications, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    FBTA-228-BPFB-8
    Universal Fieldbus Power Hub, Motherboard for Invensys FBM 228
    8 segments, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Features for best ** quality, low heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    FBTA-228-BPFB-R-4R
    Universal Fieldbus Power Hub, Motherboard for Invensys FBM 228
    4 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Features for best ** quality, low heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    KLD2-PR-Ex1.IEC1
    Fieldbus Power Repeater
    Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to FISCO, 100 mA supply of the field side, Improves the fieldbus **, Extension of the transmission distance by means of opening a new fieldbus segment
    
    EI-0D2-10Y-10B-Y1
    Intrinsically safe Ethernet Isolator
    Galvanic Isolation I.S. to non-I.S. Port, 10/100 MBit/s according to IEEE 802.3/.3u, Installation in Zone 2, Ethernet in Zone 1 or Zone 0, Standard Ethernet patch or crossover cable, DIN-Rail mounted and OEM Version
    
    KLD2-PR-Ex1.IEC
    Fieldbus Power Repeater
    Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to Entity, 70 mA supply of the field side, Improves the fieldbus **, Extension of the transmission distance by means of opening a new fieldbus segment
    
    RD0-TI-EX8.FF.ST-Y1
    Temperature Multi-Input Device for Cabinet Installation
    Temperature Multi-Input Device for Cabinet Installation
    
    MB-FB-4R.HO.SC
    High-Density Fieldbus Power Hub, Motherboard for Honeywell C-Series
    4 segments, redundant, individual modules per segment, Customized for Honeywell, C-Series, High-power trunk: Live work on devices in any hazardous area, Optimized for size and quality, low heat dissipation, For FOUNDATION Fieldbus H1
    
    DP-LBF-I1.36.*
    Fieldbus Surge Protector for Cabinet Installation, Ex ia
    Modular: protection module easy to replace, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Protection module replaceable, interrupting or non-interrupting, Grounding of shield direct or via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F*-FT-Ex1
    Fieldbus Terminator, Field Installation, Ex ia
    Terminator in stainless steel housing, Intrinsically safe, FISCO and flameproof enclosure (Ex d), Installation on open cable gland, Choice of threads 20 mm, Pg 13.5 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F*-LBF-D1.32
    Fieldbus Surge Protector, Field Installation, Ex d
    Surge Protector in stainless steel housing, Flameproof enclosure (Ex d) protection, Surge protection for '+' and '-' fieldbus lead, Choice of threads 20 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F*-LBF-I1.32
    Fieldbus Surge Protector, Field Installation, Ex ia
    Surge Protector in stainless steel housing, Intrinsically safe, FISCO or Entity, Surge protection for '+' and '-' fieldbus lead, Choice of threads 20 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.FB0.P**.A**.1.0.***.***.****
    FieldBarrier Junction Box, Polyester (GRP)
    4, 8 or 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.FB0.S**.A**.1.0.***.***.****
    FieldBarrier Junction Box, Stainless Steel
    4, 8 or 12 outputs Ex ia, Electropolished enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.FB1.P14.A**.1.*.***.***.****
    FieldBarrier Junction Box, Polyester (GRP)
    8, 10, 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.FB1.S14.A**.1.*.***.***.****
    FieldBarrier Junction Box, Stainless Steel
    8, 10, 12 outputs Ex ia, Electropolished enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.MIO.P12.*12.F.*.***.***.**00
    Multi-Input/Output Junction Box, Polyester (GRP)
    For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1
    
    F.MIO.P12.*12.P.*.***.***.**00
    Multi-Input/Output Junction Box, Polyester (GRP)
    For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA
    
    F.MIO.S12.*12.F.*.***.***.**00
    Multi-Input/Output Junction Box, Stainless Steel
    For discrete inputs and outputs, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1
    
    F.MIO.S12.*12.P.*.***.***.**00
    Multi-Input/Output Junction Box, Stainless Steel
    For discrete inputs and outputs, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA
    
    F.SP5.P**.B**.1.0.***.***.***0
    Segment Protector Junction Box, Polyester (GRP)
    4 ... 12 outputs Ex ic (FISCO or Entity), Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.SP5.S**.B**.1.0.***.***.***0
    Segment Protector Junction Box, Stainless Steel
    4 ... 12 outputs Ex ic (FISCO or Entity), Stainless steel, electropolished, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.SPE.P**.A**.1.0.***.***.****
    Segment Protector Junction Box, Polyester (GRP)
    Connection of Ex d certified devices, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.SPE.S**.A**.1.0.***.***.****
    Segment Protector Junction Box, Stainless Steel
    Connection of Ex d certified devices, Stainless steel, electropolished, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.TI0.P12.*08.F.0.***.***.**00
    Temperature Multi-Input Junction Box, Polyester (GRP)
    8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1
    
    F.TI0.P12.*08.P.0.***.***.**00
    Temperature Multi-Input Junction Box, Polyester (GRP)
    8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA
    
    F.TI0.S12.*08.F.0.***.***.**00
    Temperature Multi-Input Junction Box, Stainless Steel
    8 channel universal temperature interface, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1
    
    F.TI0.S12.*08.P.0.***.***.**00
    Temperature Multi-Input Junction Box, Stainless Steel
    8 channel universal temperature interface, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA
    
    F.VC0.P21.A04.*.*.***.***.*000
    Valve Coupler Junction Box, Polyester (GRP)
    4 valve control and 8 position feedback **s, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.VC0.S20.A04.*.*.***.***.*000
    Valve Coupler Junction Box, Stainless Steel
    4 valve control and 8 position feedback **s, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F2-JB-#.*
    Fieldbus junction box
    4 ... 8 outputs selectable, Installation in non-explosion hazardous area, Instruments in non-explosion hazardous area, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Supports FISCO and Entity
    
    F2-JB-I#.*
    Fieldbus junction box
    4 ... 8 outputs Ex ia, ib, Installation in Zone 1/Div. 1, Instruments in Zone 0...1/Div. 1, Trunk and spurs intrinsically safe, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F2-SP-IC*
    Fieldbus Segment Protector
    Fieldbus Segment Protector, 4 ... 10 outputs Ex ic (FISCO or Entity), Advanced fault isolation at the spur, Segment Protector in Zone 2, Instruments in Zone 2 or Zone 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F2D0-FB-Ex4.*
    FieldBarrier®
    4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F2D0-MIO-Ex12.FF.*
    Multi-Input/Output Device with Aluminum Housing
    For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1
    
    F2D0-MIO-Ex12.PA.*
    Multi-Input/Output Device with Aluminum Housing
    For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA
    
    F2D0-TI-Ex8.FF.*
    Temperature Multi-Input Device with Aluminum Housing
    For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
    
    F2D0-TI-Ex8.PA.*
    Temperature Multi-Input Device with Aluminum Housing
    For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
    
    MB-FB-GTR1*
    Fieldbus Power Hub, Gateway Motherboard
    For 2 gateway modules, For PROFIBUS PA, Redundant configuration, Installation in Zone 2/Class I, Div. 2, Spring terminals or screw terminals selectable
    
    MBHC-FB-4*
    Compact Fieldbus Power Hub, Motherboard, Common Interface
    4 segments, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    MBHC-FB-4.GT*
    Fieldbus Power Hub, Motherboard for Gateway and Power Supply Modules
    4 segments, simplex, individual modules per segment, For PROFIBUS PA, For gateway and power supply modules, High-power trunk: Live work on devices in any hazardous area, Optional advanced diagnostics
    
    MBHC-FB-4.HSC*
    Compact Fieldbus Power Hub, Motherboard, Host System Connector
    4 segments, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA
    
    MBHC-FB-4.YO*
    Compact Fieldbus Power Hub, Motherboard for Yokogawa ALF111
    4 segments, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    MBHC-FB-4R*
    Compact Fieldbus Power Hub Motherboard with Common Interface
    4 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    MBHC-FB-4R.HSC*
    Compact Fieldbus Power Hub, Motherboard, Host System Connector
    4 segments, redundant, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA
    
    MBHC-FB-4R.YO*
    Compact Fieldbus Power Hub Motherboard for Yokogawa ALF111
    4 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    MBHC-FB-8R*
    Compact Fieldbus Power Hub, Motherboard, Common Interface
    8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    MBHC-FB-8R.HSC*
    Compact Fieldbus Power Hub, Motherboard, Host System Connector
    8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    MBHC-FB-8R.RH*
    Compact Fieldbus Power Hub, Motherboard, Redundant Host Terminals
    8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, redundant terminals, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    MBHC-FB-8R.YO*
    Compact Fieldbus Power Hub Motherboard for Yokogawa ALF111
    8 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    R2-SP-IC*
    Segment Protector for Cabinet Installation
    4 ... 12 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2), Advanced fault isolation at the spur, Segment Protector in Zone 2/Div. 2, Instruments in Zone 2/Div. 2 or Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    R4D0-FB-IA*
    FieldBarrier® for Cabinet Installation
    FieldConnex® FieldBarrier®, 8 ... 12 outputs Ex ia IIC, FISCO and Entity, Advanced fault isolation and diagnostics at the spur, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    R8D0-MIO-Ex12.FF*
    Multi-Input/Output Device for Cabinet Installation
    For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
    
    R8D0-MIO-Ex12.PA*
    Multi-Input/Output Device for Cabinet Installation
    For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
    
    RD0-FB-Ex4.*
    FieldBarrier®
    4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    RD0-TI-Ex8.FF.*
    Temperature Multi-Input Device for Cabinet Installation
    For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
    
    RD0-TI-Ex8.PA.*
    Temperature Multi-Input Device for Cabinet Installation
    For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
    
    SCP-LBF-IA1.36.IE*
    Fieldbus Surge Protector, Field Installation on Spur
    Pluggable, mounts between device coupler and spur cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    SPJB-**-AL*.***
    Segment Protector Junction Box, Aluminum
    Intrinsically safe (Ex ic)/non-incendive outputs, Anodized aluminum, IP67, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    SPJB-**-CS*.***
    Segment Protector Junction Box, Carbon Steel
    Intrinsically safe (Ex ic)/non-incendive outputs, Carbon steel, NEMA 4, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    SPJB-**-FB*.***
    Segment Protector Junction Box, Polyester (GRP)
    Intrinsically safe (Ex ic)/non-incendive outputs, Glass fiber reinforced polyester, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    SPJB-**-PCW.***
    Segment Protector Junction Box, Polycarbonate
    Intrinsically safe (Ex ic)/non-incendive outputs, Impact resistant polycarbonate, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    SPJB-**-SS*.***
    Segment Protector Junction Box, Stainless Steel
    Intrinsically safe (Ex ic)/non-incendive outputs, Stainless steel, brushed NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    TCP-LBF-IA1.36.IE*
    Fieldbus Surge Protector, Field Installation on Trunk
    Pluggable, mounts between device coupler and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    TPH-LBF-IA1.36.DE*
    Fieldbus Surge Protector, Trunk Installation on Power Hub
    Pluggable, mounts between Power Hub and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield direct, For FOUNDATION Fieldbus H1 and PROFIBUS PA

    上海创弗实业有限公司专注于安川伺服电机,罗斯蒙特变送器罗斯蒙特分析仪,库伯勒编码器等

  • 词条

    词条说明

  • 罗斯蒙特ph电3900-01-12、3900-02-10艾默生ph玻璃电

    罗斯蒙特ph电3900-01-12、3900-02-10艾默生ph玻璃电 3900-02-10艾默生ph玻璃电 罗斯蒙特3900和3900VP pH / ORP组合传感器用于的pH或氧化/还原电位管道,露天水池或池塘中水溶液的测量。其鲁棒的传感器设计使得罗斯蒙特3900和罗斯蒙特3900VP传感器被广泛的应用。 3900:通用型 pH/ORP 传感器 3900-01-10:智能前置放大器

  • 396R-10-21-54罗斯蒙特分析仪396RVP

    396R:TUpH 可伸缩 pH/ORP 传感器罗斯蒙特分析仪396R-10-21-54罗斯蒙特分析仪396RVP 396R-10-21-54:GPLR,21" 钛管,54,1054/1055/1056/1057/6081/81/2081/3081/4081/5081/XMT/2700 (Pt-100) 396R-10-21-54-61:GPLR,21" 钛管,54,1054/1055/1056/

  • F2D0-FB-Ex4

    R2-SP 网段保护器 现场总线网段保护器-R-SP-E12 12个增加的安全输出(Ex e)1区/ Div中每个输出段保护器的短路电流限制。1区/ Div中的2台仪器。1对于基金会现场总线H1和PROFIBUS PA ... 现场总线网段保护器-F2-SP-IC * 4 ... 10输出Ex ic(FISCO或Entity)或非易燃(Div 2)区域2 / Div中的支线段保护器的故障隔离。

  • R2-SP-IC10倍加福

    R-JB-4 R2-SP-IC10倍加福 R-JB-8 R2-SP-IC10倍加福 R-JB-I6 R-SP-E12 R-SP-N12 R1-SP-N10 R1-SP-N12 R2-SP-IC10 R2-SP-IC12 R2-SP-IC4 R2-SP-IC6 R2-SP-IC8 R2-SP-N10 R2-SP-N12 R2-SP-N4 R2-SP-N6 R2-SP-N8 R3-SP-IBD12 R

联系方式 联系我时,请告知来自八方资源网!

公司名: 上海创弗实业有限公司

联系人: 张晓龙

电 话: 18001664790

手 机: 18001664790

微 信: 18001664790

地 址: 上海松江方松辰塔路2号

邮 编:

网 址: chuangfusy.b2b168.com

八方资源网提醒您:
1、本信息由八方资源网用户发布,八方资源网不介入任何交易过程,请自行甄别其真实性及合法性;
2、跟进信息之前,请仔细核验对方资质,所有预付定金或付款至个人账户的行为,均存在诈骗风险,请提高警惕!
    联系方式

公司名: 上海创弗实业有限公司

联系人: 张晓龙

手 机: 18001664790

电 话: 18001664790

地 址: 上海松江方松辰塔路2号

邮 编:

网 址: chuangfusy.b2b168.com

    相关企业
    商家产品系列
  • 产品推荐
  • 资讯推荐
关于八方 | 八方币 | 招商合作 | 网站地图 | 免费注册 | 一元广告 | 友情链接 | 联系我们 | 八方业务| 汇款方式 | 商务洽谈室 | 投诉举报
粤ICP备10089450号-8 - 经营许可证编号:粤B2-20130562 软件企业认定:深R-2013-2017 软件产品登记:深DGY-2013-3594
著作权登记:2013SR134025
Copyright © 2004 - 2024 b2b168.com All Rights Reserved