HCD2-FBPS-1.23.500 Fieldbus Power Hub, Compact Power Supply Module Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA HCD2-FBPS-1.500 Fieldbus Power Hub, Compact Power Supply Module Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA HD2-DM-A Fieldbus Power Hub, Advanced Diagnostic Module Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA HD2-GTR-4PA PROFIBUS Power Hub, Gateway Module PROFIBUS DP V1 / For 4 segments PA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Optional redundant configuration, Installation in Zone 2/Class I, Div. 2, Up to 12 Mbit/s, auto adapting KT-MB-GT2AD.FF Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PA R-SP-E12 Segment Protector for Cabinet Installation Segment Protector for Cabinet Installation, 12 increased safety outputs (Ex e), Short circuit current limitation per output, Segment Protector in Zone 1/Div. 2, Instruments in Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA ELS-1 Enclosure Leakage Sensor Housing leakage sensor, for operation with FOUNDATION Fieldbus and PROFIBUS PA, Indication via LED and Advanced Diagnostics, Intrinsically safe, FISCO or Entity, For instrument or device coupler, Fits inside terminal compartment, For FOUNDATION Fieldbus H1 and PROFIBUS PA HD2-DM-B Fieldbus Power Hub, Basic Diagnostic Module Basic monitoring for power supply output and health, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA KFD2-BR-1.PA.1500 Basic Segment Coupler Output: 24 ... 26 V/400 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, Up to 1.5 MBit auto-adapting KLD0-SAA Voltage adjustment module Series voltage reducing module, Removable terminals, Polarity reversal protected, Installation in cabinet on DIN mounting rail, For FOUNDATION Fieldbus H1 and PROFIBUS PA KLD2-FBPS-1.25.360 Fieldbus Power Supply Output: 25 ... 27 V/360 mA, For most fieldbus applications, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 BP-FBPS-1.30.1 Portable Fieldbus Battery Portable Fieldbus Battery, Adjustable output 15 ... 30 V/max.1 A , 8 hours operation at 500 mA without recharging, IP 54 - Rain and splash proof, Rugged housing for outdoor use, For FOUNDATION Fieldbus H1 and PROFIBUS PA EI-0D2-10Y-10B Intrinsically safe Ethernet Isolator Galvanic Isolation I.S. to non-I.S. Port, 10/100 MBit/s according to IEEE 802.3/.3u, Installation in Zone 2, Ethernet in Zone 1 or Zone 0, Standard Ethernet patch or crossover cable, DIN-Rail mounted and OEM Version FBTA-228-BPFB-R-8R Compact Fieldbus Power Hub Motherboard for Invensys FBM 228 8 segments, redundant, individual modules per segment, Customized for Invensys, FBM228, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 FDH-1 Fieldbus Diagnostic Handheld Fieldbus Diagnostic Handheld, Comprehensive diagnostics for the fieldbus physical layer, Handheld with display and integrated expert system, Fieldbus interface Ex ia, FISCO, Entity, and DART, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA HD2-DM-A.RO Fieldbus Power Hub, Advanced Diagnostic Module with Relay Output Diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA HD2-GTR-4PA.PN PROFINET Power Hub, Gateway Module Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnostics KFD2-BR-Ex1.3PA.93 Segment Coupler 1 Output: 12.6 ... 13.4 V/100 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Intrinsically safe, Ex ia (FISCO or Entity), Installation in Zone 2/Class I, Div. 2, Fixed, high-availability terminator KLD2-FBPS-1.12.220 Fieldbus Power Supply Output: 12 ... 13 V/220 mA, For battery or solar-powered applications, For demanding environmental conditions , Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 KLD2-PR-1.IEC Fieldbus Power Repeater Output: 24 ... 26 V/400 mA, For extension of fieldbus segments, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA KT-MB-DMA Advanced Diagnostic Module, Kit for Stand-Alone Operation Comprehensive diagnostics for the fieldbus physical layer, Module and motherboard for retrofit of any installation, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA KT-MB-GT2AD.FF.IO Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Alarm handling and integrated I/O for cabinet monitoring/control, For FOUNDATION Fieldbus and PROFIBUS PA KT-SRT-FF Starter Kit for FOUNDATION Fieldbus H1 Infrastructure Starter Kit for FOUNDATION Fieldbus H1 Infrastructure, Complete hardware for connection of FOUNDATION Fieldbus H1 field devices to the host system of your choice, Output: 25 ... 28 V/360 mA, Connection of 6 field devices with individual short-circuit protection, High-power trunk for high device count and long cable lengths KT-SRT-PA Starter Kit for PROFIBUS PA Infrastructure Starter Kit for PROFIBUS PA Infrastructure, Complete hardware for connection of PROFIBUS PA field devices to a DP-Master, Output: 24 ... 26 V/400 mA, Connection of 6 field devices with individual short-circuit protection, High-power trunk for high device count and long cable lengths MBHC-FB-4R.YO.R Compact Fieldbus Power Hub Motherboard for Yokogawa ALF111 Compact redundant Fieldbus Power Hub motherboard with redundant terminals for Yokogawa ALF111 on the right-hand side USB-FBPS-1.11.45.NI USB Fieldbus Power Supply USB Fieldbus Power Supply, Output: min. 11 V/45 mA, For 1...2 devices/test setups, In conjunction with NI PCMCIA-FBUS card, Permitted for Zone 2 operation, For FOUNDATION Fieldbus H1 HD2-FBPS-1.500 Fieldbus Power Hub, Power Supply Module Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA HD2-FBPS-1.17.500 Fieldbus Power Hub, Power Supply Module Output: 15 ... 17 V/500 mA, Voltage limitation for FISCO ic, Entity ic, also FNICO and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA HD2-FBPS-1.23.500 Fieldbus Power Hub, Power Supply Module Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA HD2-FBPS-1.25.360 Fieldbus Power Hub, Power Supply Module Output: 25 ... 28 V/360 mA, Universal power supply for most applications, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA FBTA-228-BPFB-8 Universal Fieldbus Power Hub, Motherboard for Invensys FBM 228 8 segments, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Features for best ** quality, low heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA FBTA-228-BPFB-R-4R Universal Fieldbus Power Hub, Motherboard for Invensys FBM 228 4 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Features for best ** quality, low heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA KLD2-PR-Ex1.IEC1 Fieldbus Power Repeater Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to FISCO, 100 mA supply of the field side, Improves the fieldbus **, Extension of the transmission distance by means of opening a new fieldbus segment EI-0D2-10Y-10B-Y1 Intrinsically safe Ethernet Isolator Galvanic Isolation I.S. to non-I.S. Port, 10/100 MBit/s according to IEEE 802.3/.3u, Installation in Zone 2, Ethernet in Zone 1 or Zone 0, Standard Ethernet patch or crossover cable, DIN-Rail mounted and OEM Version KLD2-PR-Ex1.IEC Fieldbus Power Repeater Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to Entity, 70 mA supply of the field side, Improves the fieldbus **, Extension of the transmission distance by means of opening a new fieldbus segment RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Device for Cabinet Installation Temperature Multi-Input Device for Cabinet Installation MB-FB-4R.HO.SC High-Density Fieldbus Power Hub, Motherboard for Honeywell C-Series 4 segments, redundant, individual modules per segment, Customized for Honeywell, C-Series, High-power trunk: Live work on devices in any hazardous area, Optimized for size and quality, low heat dissipation, For FOUNDATION Fieldbus H1 DP-LBF-I1.36.* Fieldbus Surge Protector for Cabinet Installation, Ex ia Modular: protection module easy to replace, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Protection module replaceable, interrupting or non-interrupting, Grounding of shield direct or via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA F*-FT-Ex1 Fieldbus Terminator, Field Installation, Ex ia Terminator in stainless steel housing, Intrinsically safe, FISCO and flameproof enclosure (Ex d), Installation on open cable gland, Choice of threads 20 mm, Pg 13.5 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA F*-LBF-D1.32 Fieldbus Surge Protector, Field Installation, Ex d Surge Protector in stainless steel housing, Flameproof enclosure (Ex d) protection, Surge protection for '+' and '-' fieldbus lead, Choice of threads 20 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA F*-LBF-I1.32 Fieldbus Surge Protector, Field Installation, Ex ia Surge Protector in stainless steel housing, Intrinsically safe, FISCO or Entity, Surge protection for '+' and '-' fieldbus lead, Choice of threads 20 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA F.FB0.P**.A**.1.0.***.***.**** FieldBarrier Junction Box, Polyester (GRP) 4, 8 or 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA F.FB0.S**.A**.1.0.***.***.**** FieldBarrier Junction Box, Stainless Steel 4, 8 or 12 outputs Ex ia, Electropolished enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA F.FB1.P14.A**.1.*.***.***.**** FieldBarrier Junction Box, Polyester (GRP) 8, 10, 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA F.FB1.S14.A**.1.*.***.***.**** FieldBarrier Junction Box, Stainless Steel 8, 10, 12 outputs Ex ia, Electropolished enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA F.MIO.P12.*12.F.*.***.***.**00 Multi-Input/Output Junction Box, Polyester (GRP) For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1 F.MIO.P12.*12.P.*.***.***.**00 Multi-Input/Output Junction Box, Polyester (GRP) For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA F.MIO.S12.*12.F.*.***.***.**00 Multi-Input/Output Junction Box, Stainless Steel For discrete inputs and outputs, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1 F.MIO.S12.*12.P.*.***.***.**00 Multi-Input/Output Junction Box, Stainless Steel For discrete inputs and outputs, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA F.SP5.P**.B**.1.0.***.***.***0 Segment Protector Junction Box, Polyester (GRP) 4 ... 12 outputs Ex ic (FISCO or Entity), Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA F.SP5.S**.B**.1.0.***.***.***0 Segment Protector Junction Box, Stainless Steel 4 ... 12 outputs Ex ic (FISCO or Entity), Stainless steel, electropolished, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA F.SPE.P**.A**.1.0.***.***.**** Segment Protector Junction Box, Polyester (GRP) Connection of Ex d certified devices, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA F.SPE.S**.A**.1.0.***.***.**** Segment Protector Junction Box, Stainless Steel Connection of Ex d certified devices, Stainless steel, electropolished, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA F.TI0.P12.*08.F.0.***.***.**00 Temperature Multi-Input Junction Box, Polyester (GRP) 8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1 F.TI0.P12.*08.P.0.***.***.**00 Temperature Multi-Input Junction Box, Polyester (GRP) 8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA F.TI0.S12.*08.F.0.***.***.**00 Temperature Multi-Input Junction Box, Stainless Steel 8 channel universal temperature interface, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1 F.TI0.S12.*08.P.0.***.***.**00 Temperature Multi-Input Junction Box, Stainless Steel 8 channel universal temperature interface, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA F.VC0.P21.A04.*.*.***.***.*000 Valve Coupler Junction Box, Polyester (GRP) 4 valve control and 8 position feedback **s, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA F.VC0.S20.A04.*.*.***.***.*000 Valve Coupler Junction Box, Stainless Steel 4 valve control and 8 position feedback **s, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA F2-JB-#.* Fieldbus junction box 4 ... 8 outputs selectable, Installation in non-explosion hazardous area, Instruments in non-explosion hazardous area, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Supports FISCO and Entity F2-JB-I#.* Fieldbus junction box 4 ... 8 outputs Ex ia, ib, Installation in Zone 1/Div. 1, Instruments in Zone 0...1/Div. 1, Trunk and spurs intrinsically safe, For FOUNDATION Fieldbus H1 and PROFIBUS PA F2-SP-IC* Fieldbus Segment Protector Fieldbus Segment Protector, 4 ... 10 outputs Ex ic (FISCO or Entity), Advanced fault isolation at the spur, Segment Protector in Zone 2, Instruments in Zone 2 or Zone 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA F2D0-FB-Ex4.* FieldBarrier® 4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA F2D0-MIO-Ex12.FF.* Multi-Input/Output Device with Aluminum Housing For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1 F2D0-MIO-Ex12.PA.* Multi-Input/Output Device with Aluminum Housing For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA F2D0-TI-Ex8.FF.* Temperature Multi-Input Device with Aluminum Housing For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1 F2D0-TI-Ex8.PA.* Temperature Multi-Input Device with Aluminum Housing For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA MB-FB-GTR1* Fieldbus Power Hub, Gateway Motherboard For 2 gateway modules, For PROFIBUS PA, Redundant configuration, Installation in Zone 2/Class I, Div. 2, Spring terminals or screw terminals selectable MBHC-FB-4* Compact Fieldbus Power Hub, Motherboard, Common Interface 4 segments, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 MBHC-FB-4.GT* Fieldbus Power Hub, Motherboard for Gateway and Power Supply Modules 4 segments, simplex, individual modules per segment, For PROFIBUS PA, For gateway and power supply modules, High-power trunk: Live work on devices in any hazardous area, Optional advanced diagnostics MBHC-FB-4.HSC* Compact Fieldbus Power Hub, Motherboard, Host System Connector 4 segments, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA MBHC-FB-4.YO* Compact Fieldbus Power Hub, Motherboard for Yokogawa ALF111 4 segments, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 MBHC-FB-4R* Compact Fieldbus Power Hub Motherboard with Common Interface 4 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 MBHC-FB-4R.HSC* Compact Fieldbus Power Hub, Motherboard, Host System Connector 4 segments, redundant, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA MBHC-FB-4R.YO* Compact Fieldbus Power Hub Motherboard for Yokogawa ALF111 4 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 MBHC-FB-8R* Compact Fieldbus Power Hub, Motherboard, Common Interface 8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 MBHC-FB-8R.HSC* Compact Fieldbus Power Hub, Motherboard, Host System Connector 8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 MBHC-FB-8R.RH* Compact Fieldbus Power Hub, Motherboard, Redundant Host Terminals 8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, redundant terminals, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA MBHC-FB-8R.YO* Compact Fieldbus Power Hub Motherboard for Yokogawa ALF111 8 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 R2-SP-IC* Segment Protector for Cabinet Installation 4 ... 12 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2), Advanced fault isolation at the spur, Segment Protector in Zone 2/Div. 2, Instruments in Zone 2/Div. 2 or Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA R4D0-FB-IA* FieldBarrier® for Cabinet Installation FieldConnex® FieldBarrier®, 8 ... 12 outputs Ex ia IIC, FISCO and Entity, Advanced fault isolation and diagnostics at the spur, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA R8D0-MIO-Ex12.FF* Multi-Input/Output Device for Cabinet Installation For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1 R8D0-MIO-Ex12.PA* Multi-Input/Output Device for Cabinet Installation For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA RD0-FB-Ex4.* FieldBarrier® 4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1 RD0-TI-Ex8.PA.* Temperature Multi-Input Device for Cabinet Installation For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA SCP-LBF-IA1.36.IE* Fieldbus Surge Protector, Field Installation on Spur Pluggable, mounts between device coupler and spur cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA SPJB-**-AL*.*** Segment Protector Junction Box, Aluminum Intrinsically safe (Ex ic)/non-incendive outputs, Anodized aluminum, IP67, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA SPJB-**-CS*.*** Segment Protector Junction Box, Carbon Steel Intrinsically safe (Ex ic)/non-incendive outputs, Carbon steel, NEMA 4, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA SPJB-**-FB*.*** Segment Protector Junction Box, Polyester (GRP) Intrinsically safe (Ex ic)/non-incendive outputs, Glass fiber reinforced polyester, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA SPJB-**-PCW.*** Segment Protector Junction Box, Polycarbonate Intrinsically safe (Ex ic)/non-incendive outputs, Impact resistant polycarbonate, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA SPJB-**-SS*.*** Segment Protector Junction Box, Stainless Steel Intrinsically safe (Ex ic)/non-incendive outputs, Stainless steel, brushed NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA TCP-LBF-IA1.36.IE* Fieldbus Surge Protector, Field Installation on Trunk Pluggable, mounts between device coupler and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA TPH-LBF-IA1.36.DE* Fieldbus Surge Protector, Trunk Installation on Power Hub Pluggable, mounts between Power Hub and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield direct, For FOUNDATION Fieldbus H1 and PROFIBUS PA
词条
词条说明
罗斯蒙特ph电3900-01-12、3900-02-10艾默生ph玻璃电
罗斯蒙特ph电3900-01-12、3900-02-10艾默生ph玻璃电 3900-02-10艾默生ph玻璃电 罗斯蒙特3900和3900VP pH / ORP组合传感器用于的pH或氧化/还原电位管道,露天水池或池塘中水溶液的测量。其鲁棒的传感器设计使得罗斯蒙特3900和罗斯蒙特3900VP传感器被广泛的应用。 3900:通用型 pH/ORP 传感器 3900-01-10:智能前置放大器
396R:TUpH 可伸缩 pH/ORP 传感器罗斯蒙特分析仪396R-10-21-54罗斯蒙特分析仪396RVP 396R-10-21-54:GPLR,21" 钛管,54,1054/1055/1056/1057/6081/81/2081/3081/4081/5081/XMT/2700 (Pt-100) 396R-10-21-54-61:GPLR,21" 钛管,54,1054/1055/1056/
R2-SP 网段保护器 现场总线网段保护器-R-SP-E12 12个增加的安全输出(Ex e)1区/ Div中每个输出段保护器的短路电流限制。1区/ Div中的2台仪器。1对于基金会现场总线H1和PROFIBUS PA ... 现场总线网段保护器-F2-SP-IC * 4 ... 10输出Ex ic(FISCO或Entity)或非易燃(Div 2)区域2 / Div中的支线段保护器的故障隔离。
R-JB-4 R2-SP-IC10倍加福 R-JB-8 R2-SP-IC10倍加福 R-JB-I6 R-SP-E12 R-SP-N12 R1-SP-N10 R1-SP-N12 R2-SP-IC10 R2-SP-IC12 R2-SP-IC4 R2-SP-IC6 R2-SP-IC8 R2-SP-N10 R2-SP-N12 R2-SP-N4 R2-SP-N6 R2-SP-N8 R3-SP-IBD12 R
公司名: 上海创弗实业有限公司
联系人: 张晓龙
电 话: 18001664790
手 机: 18001664790
微 信: 18001664790
地 址: 上海松江方松辰塔路2号
邮 编: