摘要:本文介绍了安科瑞DJSF1352-RN直流电表在俄罗斯UPS计量系统中的应用。主要用于UPS系统中的输出电能的计量,通过霍尔对电路系统进行计量、通讯和控制等。
Abstract: This article introduces the application of “Acrel” DJSF1352-RN DC meter in the Russian UPS metering system. It is mainly used for the measurement of the output energy in the UPS system, and the measurement, communication and control of the circuit system through the Hall sensor.
1.项目概述:Project Overview
该公司位于俄罗斯,是一家电池生产公司。主要在俄罗斯从事工业电池及UPS的生产和供应。客户要使用直流电表,用于UPS输出端电能的监测计量。
The company is located in Russia and is a battery production company. Mainly engaged in the production and supply of industrial batteries and UPS in Russia. The customer needs to use a DC meter for monitoring and measuring the electrical energy at the output of the UPS.
2.DJSF1352-RN介绍 DJSF1352-RN DC Energy Meters
DJSF1352-RN导轨式直流电能表,主要针对电信基站、直流充电桩、太阳能光伏等应用场合而设计,该系列仪表可测量直流系统中的电压、电流、功率以及正反向电能等。在实际使用现场,即可计量总电能,又可计量规定时间段内的电能。检测的结果既可用于本地显示,又能与工控设备、计算机连接,组成测控系统。
仪表可具有红外通讯接口和RS-485通讯接口,同时支持Modbus-RTU协议和DLT645-97(07)协议;可带继电器警报输出和开关量输入功能;根据不同要求,通过仪表面板按键,对变比、警报、通讯进行设置;具有开关量事件记录(Modbus协议)、编程和事件设置记录(645协议)、数据瞬时和定时冻结功能(645协议)、电压电流功率峰值、谷值记录功能。
3.型号及功能介绍 Type and Function Description
Note:when dual DC input(D)function is selected,if Hall current sensor input is used in current channel, a power supply module shall be provided to supply power to the second Hall sensor; if D function is not provided, the built-in power supply of electric meter can be used.
Technical parameters | Index | ||||
Input | Nominal value | Voltage input range | Current input | ||
DC 0-1000V | Hall sensor:0-20mA、4-20mA、0-5V,0-10V and so on. | ||||
Overload | 1.2 times rated (continuous); 2 times rated/1 second; | ||||
Power consumption | Voltage: ≤0.2VA, current ≤0.1VA | ||||
Accuracy class | Class 1 | ||||
Function | Display | 8-bit segment LCD screen (LCD) | |||
Communication Interface | RS485(two options) | ||||
Communication protocol | Modbus-RTU,DL/T 645-2007 | ||||
Switch | Switch output | 2 Relay outputs, 2A/30VDC or 2A/250VAC | |||
Switch input | 2 dry contact inputs | ||||
Pulse output | A second pulse output, a energy pulse output | ||||
See the SYS->PLUS display in the meter menu settings. For example: The meter displays 100, which is 100imp/kWh | |||||
Power Supply | Voltage range | AC/DC 85-265V or DC24V(±10%) or DC48V(±10%) | |||
Power consumption | ≤ 3W | ||||
Power frequency withstand voltage | Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output 3kV/1min Power supply // Relay output // Voltage input // Current input 3kV/1min Pulse output // Communication interface // Switch input 2kV/1min | ||||
Impulse withstand voltage | ±6KV | ||||
Insulation resistance | ≥ 40M Ω | ||||
Average barrier-free working hours | ≥50000h | ||||
Environment | Temperature | Normal operating temperature: -25 °C ~ +65 °C; Limit working temperature: -40 °C ~ +70 °C; Storage temperature: -40℃~+80℃ | |||
Humidity | ≤93%RH, no condensation, no corrosive gas | ||||
Altitude | ≤2500m |
4.客户要求 Customer Requirements
客户想计量UPS的实际输出电能,来计算UPS储能与耗能的转化比,UPS输入端用的是我们ADL系列的电表,输出端用的是DJSF1352-RN直流电表,通过分流器采取电信号,达到输出端测量的目的
参考文献 Bibliography
1.Solutions For Enterprise Micro-grid System 2021.04
相关产品:多功能电表、导轨式智能电表、无线电表、4G电表、NB电表、电机保护器、马达保护器、线路保护器、预付费电表、无线测温、电房无人值守系统、配电室综合监控系统、电能管理系统、能耗管理系统、用电管理系统、能源信息化系统、预付费管理系统
词条
词条说明
摘要:本文分析了霍尔传感器在光伏汇流箱的应用,光伏汇流箱是光伏发电的重要组成部分,主要用于太阳能光伏组件与直流控制柜间的连接。使用霍尔电流传感器可以实现太阳能光伏组件阵列的电流隔离测量,准确测量光伏汇流箱输出直流电流。 关键词:光伏汇流箱;霍尔电流传感器;隔离;光伏发电 0:概述 随着能源结构调整步伐的加快,国家大力提倡绿色能源,太阳能光伏产业飞速发展。在太阳能发电站运行过程中,准确测量光电池板输
摘要:采用微机保护和多功能电力仪表、采集变电所内10KV高压柜以及0.4KV低压配电回路现场的各种电参量和开关信号。系统采用现场就地组网的方式,组网后通过现场总线通讯并远传至后台,通过Acrel-2000型电力监控系统实现配电所配电回路用电的实时监控和管理。关键词:商业建筑;变电所 ;Acrel-2000;电力监控系统;0 概述攀枝花银泰城北地块项目位于攀枝花市仁和区攀枝花大道南段与云盘
摘要:配电系统是由多种配电设备和配电设施所组成的变换电压和直接向终端用户分配电能的一个电力网络系统。由于配电系统作为电力系统的一个环节直接面向终端用户,它的完善与否直接关系着广大用户的用电可靠性和用电质量,因而在电力系统中具有重要的地位。因此,为避免因温度高,导致设备老化,设备烧坏,供电中断,一次设备起*炸等严重事故,对各电气节点进行长期的温度监测能避免因严重故障,造成用户的人身伤害及经济损失。
摘要:数据中心供电电源质量的好坏直接影响到IT设备的安全运行,因此对数据中心直流列头柜电源进出线实行监测非常重要,而通过霍尔电流传感器可以采集主进线电流、多路支路直流电流和漏电流。 关键词:数据中心;直流列头柜;霍尔电流传感器 0.概述 直流列头柜是一款针对数据中心机房能源末端,综合采集所有能源数据的智能配电柜。为终端能源监测系统提供高精度测量数据,通过显示单元,实时反映电能质量数据,并通过 R
公司名: 江苏安科瑞电器制造有限公司
联系人: 潘经理
电 话:
手 机: 18706168052
微 信: 18706168052
地 址: 江苏无锡江阴市江阴市南闸街道东盟路5号
邮 编:
网 址: hanna.cn.b2b168.com
公司名: 江苏安科瑞电器制造有限公司
联系人: 潘经理
手 机: 18706168052
电 话:
地 址: 江苏无锡江阴市江阴市南闸街道东盟路5号
邮 编:
网 址: hanna.cn.b2b168.com