摘要:本文介绍了安科瑞DJSF1352-RN直流电表在俄罗斯UPS计量系统中的应用。主要用于UPS系统中的输出电能的计量,通过霍尔对电路系统进行计量、通讯和控制等。
Abstract: This article introduces the application of “Acrel” DJSF1352-RN DC meter in the Russian UPS metering system. It is mainly used for the measurement of the output energy in the UPS system, and the measurement, communication and control of the circuit system through the Hall sensor.
1.项目概述:Project Overview
该公司位于俄罗斯,是一家电池生产公司。主要在俄罗斯从事工业电池及UPS的生产和供应。客户要使用直流电表,用于UPS输出端电能的监测计量。
The company is located in Russia and is a battery production company. Mainly engaged in the production and supply of industrial batteries and UPS in Russia. The customer needs to use a DC meter for monitoring and measuring the electrical energy at the output of the UPS.
2.DJSF1352-RN介绍 DJSF1352-RN DC Energy Meters
DJSF1352-RN导轨式直流电能表,主要针对电信基站、直流充电桩、太阳能光伏等应用场合而设计,该系列仪表可测量直流系统中的电压、电流、功率以及正反向电能等。在实际使用现场,即可计量总电能,又可计量规定时间段内的电能。检测的结果既可用于本地显示,又能与工控设备、计算机连接,组成测控系统。
仪表可具有红外通讯接口和RS-485通讯接口,同时支持Modbus-RTU协议和DLT645-97(07)协议;可带继电器警报输出和开关量输入功能;根据不同要求,通过仪表面板按键,对变比、警报、通讯进行设置;具有开关量事件记录(Modbus协议)、编程和事件设置记录(645协议)、数据瞬时和定时冻结功能(645协议)、电压电流功率峰值、谷值记录功能。
DJSF1352-RN rail-mounted DC power meter designed for telecommunications base stations, DC charging piles, solar photovoltaic and other applications, this series of meters can measure the voltage, current, power and forward and reverse energy and so on in the DC system.The actual use of the site, you can measure the total power, but also measure the energy within a specified period of time. The test results can be used for local display, but also with industrial control equipment, computers to form a measurement and control system.
The meter can have infrared communication interface and RS-485 communication interface, and supports Modbus-RTU protocol and DLT645-97 (07) protocol at the same time.The meter can have relay alarm output and digital input function;You can set the ratio, alarm, and communication through the meter panel keys according to different requirements.The meter can have event recording of switch (Modbus protocol), programming and event setting records (645 protocol), instantaneous and timing freeze function of data (645 protocol), maximum and minimum value recording function of voltage and current power.
3.型号及功能介绍 Type and Function Description
Note:when dual DC input(D)function is selected,if Hall current sensor input is used in current channel, a power supply module shall be provided to supply power to the second Hall sensor; if D function is not provided, the built-in power supply of electric meter can be used.
4.客户要求 Customer Requirements
客户想计量UPS的实际输出电能,来计算UPS储能与耗能的转化比,UPS输入端用的是我们ADL系列的电表,输出端用的是DJSF1352-RN直流电表,通过分流器采取电信号,达到输出端测量的目的。
The customer wants to measure the actual output power of the UPS to calculate the conversion ratio of UPS energy storage to energy consumption. The UPS input end uses our ADL series electric meter, the output end uses DJSF1352-RN DC meter, and the electrical ** is taken through the shunt in order to achieve the purpose of output measurement.
参考文献 Bibliography
1.Solutions For Enterprise Micro-grid System 2021.04
词条
词条说明
摘要:随着国家电网改革政策的逐步推进和落实,AcrelCloud-1000变电所运维云平台运用互联网和大数据技术,为公共建筑提供变电所运维云平台。该平台基于WEB开发,使用云平台,手机APP作为配电管理人员的管控工具,实时的监视公共建筑配电系统的运行状态和电量数据。平台提供用户概况、电力数据监测、电能质量分析、用电分析、日/月/年用能数据报表、异常事件报警和记录、运行环境监测、运维派单等功能,并支
1、 光伏并网柜简介分布式并网光伏系统是利用光伏组件将太阳能直接转变为电能的发电方式,并且能一定程度保证发电的稳定性、可靠性及供给配电网电能质量,是一种新型的、环保型且具有长远发展前景的发电系统。该系统在用户所在场地或附近建设运行,以用户侧自发自用为主、多余电量上网且在配电网系统平衡调节为特征的光伏发电设施。它能够就近逐步解决用户的用电问题,通过并网送去实现供电差额的补偿与外送。光伏电源
摘要:山西某人民医院中,设备功率因数在0.8左右,供电局依据功率因数增减收费,功率因数小于0.9,电费增收,功率因数大于0.9电费减收,因此安装AZCL智能集成式电力电容器进行无功补偿、提高功率因数对企业发展是必不可少的。关键词:低压智能电力电容器,无功补偿,功率因数1:概述对于电力系统中的供电部分,提供电能的发电机是按要求的额定电压和额定电流设计的,发电机长期运行中,电压和电流都不能过额定值,
【摘要】:智能照明系统逐渐在数据中心设计和建设中落地,且应用场景不断丰富,同时也逐步在数据中心改造中进行体现。结合数据中心照明系统的实际案例,分析不同的照明模式的优缺点,为数据中心智能照明的应用进行探索。在进行智能照明系统的建设和改造中,数据中心的建设和管理者应该从节能、成本和运维管理等方面综合考虑,并充分利用现场条件。相信智能照明系统将以多样化的形式应用在数据中心中。【关键词】:数据中心;照明;
公司名: 江苏安科瑞微电网研究院有限公司
联系人: 陈雯
电 话:
手 机: 18761503718
微 信: 18761503718
地 址: 江苏无锡江阴市东盟路5号
邮 编:
网 址: acrelcw.b2b168.com