安科瑞DJSF1352-RN直流电表在尼日利亚太阳能混合动力系统的应用

    摘要:本文介绍了安科瑞DJSF1352-RN直流电表在尼日利亚小型光伏发电设施直流侧的应用。主要用于光伏系统中的电流的计量,通过霍尔对电路系统进行计量、通讯和控制等。

    Abstract: This paper introduces the application of Acrel DJSF1352-RN DC energy meter in the DC side of a photovoltaic system in Nigeria. It is mainly used to measure the DC current in the photovoltaic system, and cooperate with hall current sensor to measure, communicate and control the circuit system.

    1.项目概述:Project Overview

    该公司位于尼日利亚,是一家新能源公司。主要在非洲从事光伏发电项目。客户要使用直流电表,用于光伏系统中直流侧的监测计量。

    The company is located in Nigeria and is a new energy company. Mainly engaged in photovoltaic power generation projects in Africa. The customer wants to use DC meters and hall sensors for monitor current and voltage at the DC side of photovoltaic system.

    2.DJSF1352-RN介绍 DJSF1352-RN DC Energy Meters

    DJSF1352-RN导轨式直流电能表,主要针对电信基站、直流充电桩、太阳能光伏等应用场合而设计,该系列仪表可测量直流系统中的电压、电流、功率以及正反向电能等。在实际使用现场,即可计量总电能,又可计量规定时间段内的电能。检测的结果既可用于本地显示,又能与工控设备、计算机连接,组成测控系统。

    仪表可具有红外通讯接口和RS-485通讯接口,同时支持Modbus-RTU协议和DLT645-97(07)协议;可带继电器报警输出和开关量输入功能;根据不同要求,通过仪表面板按键,对变比、报警、通讯进行设置;具有开关量事件记录(Modbus协议)、编程和事件设置记录(645协议)、数据瞬时和定时冻结功能(645协议)、电压电流功率值记录功能。

    DJSF1352-RN rail-mounted DC power meter designed for telecommunications base stations, DC charging piles, solar photovoltaic and other applications, this series of meters can measure the voltage, current, power and forward and reverse energy and so on in the DC system.The actual use of the site, you can measure the total power, but also measure the energy within a specified period of time. The test results can be used for local display, but also with industrial control equipment, computers to form a measurement and control system.

    The meter can have infrared communication interface and RS-485 communication interface, and supports Modbus-RTU protocol and DLT645-97 (07) protocol at the same time.The meter can have relay alarm output and digital input function;You can set the ratio, alarm, and communication through the meter panel keys according to different requirements.The meter can have event recording of switch (Modbus protocol), programming and event setting records (645 protocol), instantaneous and timing freeze function of data (645 protocol), value recording function of voltage and current power.

    3.型号及功能介绍 Type and Function Description

    Note:when dual DC input(D)function is selected,if Hall current sensor input is used in

    current channel,a power supply module shall be provided to supply power to the second Hall sensor;if D function is not provided,the built-in power supply of electric meter can be used.

    4.开口式霍尔电流传感器Split Core Hall Current Transformer


    5.客户要求 Customer Requirement

    客户有一个太阳能混合动力系统。PV板,电池储能与柴油发生器电信站,三者连接到同一根母线。客户想用直流仪表来监测母线的电流电压。他们的太阳能系统是电信基站,辅助电源是DC48V,电流是DC100A。

    The customer have a solar hybrid system. PV panel, battery storage and diesel generator for a telecom station,All the 3 systems are connected to a single bus bar. They wants to know the watt hour reading from the bus bar using a DC meter. And their solar site is a telecom site. the power supply voltage is DC 48V, the current is DC100A.

    参考文献 Bibliography

    1.Solutions For Enterprise Micro-grid System 2021.04


    江苏安科瑞电器制造有限公司专注于电瓶车充电桩,多回路电能表,多回路预付费电表,多用户电能计量表,有源电力滤波器,直流列头柜等

  • 词条

    词条说明

  • 南京绿溢大厦远程预付费系统项目的设计与应用

    摘要: 本远程预付费管理系统采用智能远程预付费电表(DTSY1352/DDSY1352系列),采集各商户实时用电量、剩余电量,通过智能远程预付费电表进行远程分合闸控制,实现先售电后用电。该系统采用总线通讯传至后台,通过安科瑞(AcrelCloud3200)远程预付费能源管理系统实现各商户用电的收费、监控和管理。关键词:预付费电表,DTSY1352/DDSY1352,AcrelCloud3200,总

  • Acrel-2000E配电室综合监控系统

    一、系统研发背景及简介 配电室综合监控是整个电能管理系统中的一个重要环节。目前,配电室一般都采取无人值守,定时巡查制度,这样既浪费人力物力也无法做到对配电室的环境和安全实时监控。而配电室的环境稳定可靠对变压器等设备的正常运行至关重要。 安科瑞电气股份有限公司根据配电室实际情况,结合多年的变电站和配电室的运行管理经验,*了安科瑞配电室综合监控系统,实现了智能开关柜运行监控、高压开关柜带电显示、

  • 远程预付费电能管理系统在星湖101广场的设计与应用

    摘要:介绍星湖101广场远程预付费电能管理系统,采用智能远程预付费电度表,采集各商户实时用电量、剩余电量,通过智能远程预付费电度表进行远程分合闸控制,实现先售电后用电。系统采用总线通讯传至后台,通过安科瑞Acrel-3200型远程预付费电能管理系统实现各商户用电的收费、监控和管理。0 概述 本项目是为星湖101广场项目设计一套智能用电计量管理系统,本系统主是针本对商户用电的性质,实现商户

  • 【多用户电能计量表】多用户电能表的检修方法

    用户电能表检查电源内含有的电容的时候,需要提前做好一项准备工作,先将电容短路,这个过程不能随意操作,要用特定的方式完成,否则很*烧断芯。所以,在操作的时候,可以用引线来进行,将小灯泡接在两端,直到发出光亮操作即可停止。而功耗正常的表计占比 77.03%,异常原因需经长期监控电池功耗,解剖分析。经研究,在客户检测端出现的电池欠压问题主要表现为功耗大,属制程问题,而挂网后出现的电池欠压主要为“来料”

联系方式 联系我时,请告知来自八方资源网!

公司名: 江苏安科瑞电器制造有限公司

联系人: 吴雅芳

电 话:

手 机: 18706162527

微 信: 18706162527

地 址: 江苏无锡江阴市江苏省江阴市南闸街道东盟路5号

邮 编:

网 址: nndsaf.cn.b2b168.com

八方资源网提醒您:
1、本信息由八方资源网用户发布,八方资源网不介入任何交易过程,请自行甄别其真实性及合法性;
2、跟进信息之前,请仔细核验对方资质,所有预付定金或付款至个人账户的行为,均存在诈骗风险,请提高警惕!
    联系方式

公司名: 江苏安科瑞电器制造有限公司

联系人: 吴雅芳

手 机: 18706162527

电 话:

地 址: 江苏无锡江阴市江苏省江阴市南闸街道东盟路5号

邮 编:

网 址: nndsaf.cn.b2b168.com

    相关企业
    商家产品系列
  • 产品推荐
  • 资讯推荐
关于八方 | 八方币 | 招商合作 | 网站地图 | 免费注册 | 一元广告 | 友情链接 | 联系我们 | 八方业务| 汇款方式 | 商务洽谈室 | 投诉举报
粤ICP备10089450号-8 - 经营许可证编号:粤B2-20130562 软件企业认定:深R-2013-2017 软件产品登记:深DGY-2013-3594
著作权登记:2013SR134025
Copyright © 2004 - 2024 b2b168.com All Rights Reserved