You can use pulse width modulation (PWM) to generate periodic pulses with a constant rated voltage and a variable pulse duration.
Possible applications for pulse width modulation (PWM):
Control of proportional valves and directional valves
- Energy savings as a result of a reduction in holding current or for controlling the valve position
Heating control, for example, via an external additional power unit
With pulse width modulation, a ** with defined time period and variable pulse duration is output at the digital output. You use pulse width modulation to vary the mean value of the output voltage. This allows you to control the load current or the power in line with the connected load. The pulse duration can be between 0 (no pulse, always off) and full-scale deflection (no pulse, always on).
① | Period |
② | Pulse duration |
Pulse width modulation (PWM) is based on the specification of a base frequency of 1, 2, 4, 8 or 16 kHz. You can alter the base frequency in terms of period and pulse-pause ratio over the control interface (32-bit value). The bit pattern is shown in each base period. The base period is defined on the basis of the base frequency. A "0" is LOW and a "1" is HIGH.
Base frequency: 1 kHz → Base period: 1 ms
1111 0000 0000 0000 1111 0000 0000 0000
Time period: 500 µs; 375 µs LOW; 125 µs HIGH
图片: Pulse width modulation
Base frequency: 1 kHz
1111 1111 1111 1111 0000 0000 0000 0000
Time period: 1 ms; 500 µs LOW; 500 µs HIGH
1111 1111 0000 0000 0000 0000 0000 0000
Time period: 1 ms; 750 µs LOW; 250 µs HIGH
1111 0000 1111 0000 1111 0000 1111 0000
Time period: 250 µs; 125 µs LOW; 125 µs HIGH
Base frequency: 2 kHz
1010 1010 1010 1010 1010 1010 1010 1010
Time period: 31.25 µs; 15.625 µs LOW; 15.625 µs HIGH
To configure PWM operating mode, first define the required base frequency of pulse width modulation. You can configure the base frequency as 1, 2, 4, 8 or 16 kHz. The selected base frequency then applies to all channels of interface X142.
图片: Base frequency of pulse width modulation
Now select the channels for PWM operating mode. If you want to configure very short pulses, enable the high-speed output function.
图片: Pulse width modulation channel
The selected digital output is switched with the selected base frequency and the switching pattern from the control interface.
You can invert the 24 V ** to adjust it to your process. By default, the ** is not inverted.
If you select the high-speed output option, the digital output is switched alternately to 24 V DC and ground. Allows for extremely steep edges (output delay in the 1 μs range).
To allow **s pending very briefly to be output with pulse width modulation (for example, level duration of 0.1 ms), you must operate the output as a high-speed output.
词条
词条说明
6ES7217-1AG40-0XB0SIMATIC S7-1200,CPU 1217C, 紧凑型 CPU,DC/DC/DC, 2 个 PROFINET 端口 机载 I/O: 10 DI 24V DC;4 DI RS-422/485; 6 DO 24V DC;0.5A; 4 DO RS-422/485; 2 AI 0-10V DC,2 AO 0-20mA 电源:直流 20.4-28.8V DC, 程
移植 IEC 定时器和 IEC 计数器更新 IEC 定时器在 S7-300/400 中,程序中运行该 IEC 定时器时确定的 IEC 定时器 TP、TON 和 TOF 的输出“Q”和“ET”。此后,“Q”和“ET”的状态将保持不变。如果在程序中多次访问这些输出,则收到的值始终相同。在 S7-1500 中,这个现象有所改变:每次访问时该定时器时,程序都将检查当前的定时器值,并重新确定“Q”和“ET”
SINAMICS G120、G120C、G120XA变频器都具有PID工艺控制器,PID闭环控制广泛的应用在恒压、恒温、恒流等控制场合。工艺控制器输入输出的工艺单位默认是以[%]显示,为了操作人员方便操作和观察,需要将工艺单位切换成[bar]、[m3/min]、[℃]等实际物理量。实验产品 ● SINAMICS G120XA ● 智能操作面板IOP-2:固件V2.2主要参数说明
修复已安装产品具有通过安装程序完全重新安装已安装产品进行修复的选项。要求PG/PC 的硬件和软件满足系统要求。具有计算机的管理员权限。关闭所有正在运行的程序。步骤要修复已安装的产品,请执行以下步骤:将安装介质插入相应的驱动器。安装程序将自动启动,除非在 PG/PC 上禁用了自动启动功能。如果安装程序没有自动启动,则可通过双击“Start.exe”文件手动启动。将打开选择安装语言的对话框。选择希望用
公司名: 上海腾希电气技术有限公司
联系人: 田礼科
电 话: 021-37660026
手 机: 13681875601
微 信: 13681875601
地 址: 上海松江上海市松江区广富林路4855弄星月大业**88号4楼
邮 编:
网 址: shtxjd.cn.b2b168.com
公司名: 上海腾希电气技术有限公司
联系人: 田礼科
手 机: 13681875601
电 话: 021-37660026
地 址: 上海松江上海市松江区广富林路4855弄星月大业**88号4楼
邮 编:
网 址: shtxjd.cn.b2b168.com