6ES7513-1FL02-0AB0


    The CPU for standard and fail-safe applications with medium/high requirements for program/data storage in the S7-1500 Controller product range

    Can be used for safety functions up to SIL 3 according to IEC 61508 and up to PLe according to ISO 13849

    High processing speed for binary and floating-point arithmetic

    Used as central PLC in production lines with central and distributed I/O

    Supports PROFIsafe in centralized and distributed configuration 

    PROFINET IO IRT interface with 2-port switch

    PROFINET IO controller for operating distributed I/O on PROFINET

    PROFINET I-Device for connecting the CPU as an intelligent PROFINET device under a SIMATIC or non-Siemens PROFINET IO controller

    Isochronous mode


    Note:
    SIMATIC Memory Card required for operation of the CPU

    应用

    The CPU 1513F-1 PN is the CPU with a medium to large program and data memory for standard and fail-safe applications that also contain distributed automation structures alongside central I/O. It can be used as a PROFINET IO controller or as distributed intelligence (PROFINET I-Device). The integrated PROFINET IO IRT interface is designed as a 2-port switch, enabling a linear topology to be set up in the system. In addition, the CPU offers comprehensive control functionalities as well as the ability to connect drives via standardized PLCopen blocks.

    设计

    The CPU 1513F-1 PN has:


    A powerful processor:
    The CPU achieves a command execution time as low as 40 ns per binary command.

    Extensive work memory:
    450 KB for program, 1.5 MB for data

    SIMATIC Memory Cards as load memory;
    permit additional functions such as Datalog and Archive Flexible

    Expansion capability:
    single-tier configuration with max. 32 modules (CPU + 31 modules)

    Display with functions for


    Display of overview information such as station name, higher level designation, location designation, etc.

    Showing diagnostic information

    Showing module information

    Showing display settings

    Setting IP addresses

    Setting date and time

    Switching the operating mode

    Resetting the CPU to factory settings

    Disabling/enabling the display

    Enabling of protection levels

    Display of safety mode, overall signature and date of the last download with signature change



    PROFINET IO IRT interface for connecting distributed I/O via PROFINET

    Supports PROFIsafe in centralized and distributed configuration


    功能


    Performance


    Faster command processing, depending on the CPU type, lange extensions and new data types

    Even shorter response times of the CPUs due to considerably faster backplane bus

    Powerful network connection:
    Each CPU is equipped with PROFINET IO IRT (2-port switch) as standard interface.



    Integrated technology


    Connection of analog and PROFIdrive-capable drives via standardized blocks (PLCopen)

    Support of speed-controlled and positioning axes as well as external encoders

    Trace functions for all CPU tags, both for diagnostics in real time and for sporadic error detection

    Comprehensive control functionalities, e.g. easily configurable blocks for automatic optimization of the control parameters for optimum control quality



    Security Integrated


    Password-based know-how protection against unauthorized read-out and modification of program blocks

    Copy protection for tying individual blocks to the serial number of the SIMATIC Memory Card: The block can only run if the configured memory card is inserted in the CPU.

    4-level authorization concept:
    Communication to operator panels can also be restricted.

    Manipulation protection:
    The controller recognizes changed or unauthorized transmissions of the engineering data.



    Design and handling


    Display of overview information:
    E.g. Station name, plant designation, location identifier, etc., diagnostic information, module information, display settings.

    Possible operations on the display:
    Set addresses, set date and time, select operating mode of CPU, reset CPU to factory settings, disable/enable display, activate protection levels.



    Integrated system diagnostics


    System diagnostics information is displayed consistently and in plain text in the display, TIA Portal, operator panels and web server, even for messages from the drives, and updated even if the CPU is in STOP mode.

    Integrated in the firmware of the CPU, no special configuration is required



    SIMATIC Memory Card (required for operation of the CPU)


    Used as plug-in load memory or for updating the firmware.

    Also for storing additional documents or csv files (for recipes and archives)

    Creation of data blocks for storage/reading of data via SFCs of the user program



    Datalog (archives) and recipes


    Storage of csv files for recipes and archives on the SIMATIC Memory Card;
    easy access to plant-relevant operating data using Office tools and via web server

    Easy access to configuration data of the machine by means of a web browser or SD card reader (two-way data exchange from and to the PLC)



    Programming of the standard program section


    Programming as of STEP 7 V12 SP1



    Programming of the fail-safe program section


    Programming of the safety-related program section with the "STEP 7 Safety Advanced" option package. STEP 7 Safety Advanced V12 can run under SIMATIC STEP 7 Professional V12 SP1.





    上海腾希电气技术有限公司专注于西门子PLC,V90伺服,V20变频器等, 欢迎致电 13681875601

  • 词条

    词条说明

  • OSPFv3 组态

    组态简介在此页面中组态使用 OSPFv3 实现的路由功能。提示此功能只适用于* 3 层。显示框说明该页面包含以下框:OSPFv3启用或禁用使用 OSPFv3 实现的路由功能。路由器 ID (Router ID)输入其中任一 OSPFv3 接口的名称。路由器 ID 以 IPv4 格式进行*,并且在网络中必须一。边界路由器 (Border Router)显示 OSPFv3 路由器的状态。如果本地系

  • 创建标准机器项目 概述

    概述简介标准机器项目是使用一组创新功能的 STEP 7 项目,它们支持轻松组态和调试标准机器或具有模块化结构的机器的灵活自动化解决方案。硬件组态包含作为 IO 控制器的 S7-1500 CPU 以及作为“PROFINET IO 系统主站”的已连接 IO 设备。 该主站使用较大组态进行组态,可以根据该较大组态为不同的标准机器派生不同的选项,例如 IO 系统随组态的不同而异。全面提升所有级别的灵活性标

  • R/H 系统中“在线工具”任务卡的扩展

    R/H 系统中“在线工具”任务卡的扩展概述如果两个 CPU 中的一个存在在线连接,则“在线工具”(Online tools) 任务卡中将显示 S7-1500R/H 系统信息。该任务卡由以下窗格组成:R/H 系统操作面板两个 CPU,每个 CPU 一个操作面板周期时间存储器R/H 系统操作面板“R/H 系统操作面板”(R/H system operator panel) 中将显示 R/H 系统当前状

  • 基于SIMATIC NET 的OPC通信,如何手动在WINCC中直接创建变量

    通常情况下,配置完SIMATIC NET后,我们会通过SIMATIC NET自带 OPC Client 端软件 OPC Scout创建变量,然后通过WINCC创建连接来访问OPC Scout中创建的变量。场景1:OPC Scout由于软件安装的问题,创建变量时没有DB块,无法增加V区的寄存器地址;场景2:在PC与S7-200SMART未联网情况下,OPC Scout中也没有DB块;对于以上两种情况

联系方式 联系我时,请告知来自八方资源网!

公司名: 上海腾希电气技术有限公司

联系人: 田礼科

电 话: 021-37660026

手 机: 13681875601

微 信: 13681875601

地 址: 上海松江上海市松江区广富林路4855弄星月大业**88号4楼

邮 编:

网 址: shtxjd.cn.b2b168.com

八方资源网提醒您:
1、本信息由八方资源网用户发布,八方资源网不介入任何交易过程,请自行甄别其真实性及合法性;
2、跟进信息之前,请仔细核验对方资质,所有预付定金或付款至个人账户的行为,均存在诈骗风险,请提高警惕!
    联系方式

公司名: 上海腾希电气技术有限公司

联系人: 田礼科

手 机: 13681875601

电 话: 021-37660026

地 址: 上海松江上海市松江区广富林路4855弄星月大业**88号4楼

邮 编:

网 址: shtxjd.cn.b2b168.com

    相关企业
    商家产品系列
  • 产品推荐
  • 资讯推荐
关于八方 | 八方币 | 招商合作 | 网站地图 | 免费注册 | 一元广告 | 友情链接 | 联系我们 | 八方业务| 汇款方式 | 商务洽谈室 | 投诉举报
粤ICP备10089450号-8 - 经营许可证编号:粤B2-20130562 软件企业认定:深R-2013-2017 软件产品登记:深DGY-2013-3594
著作权登记:2013SR134025
Copyright © 2004 - 2024 b2b168.com All Rights Reserved