阴极保护系统维护中的安全防护
人的生命只有一次,所有工作开始前,都要对安全进行评估,对风险进行识别。做到不安全的环境绝不开始工作,确实做到三思而后行。
一、人身防护
要穿戴适合的劳动保护服装、佩戴眼镜等,做好人身安全防护。工作张弛有度,保证饮食、营地环境卫生。夏天防止高温中暑,冬天防止寒冷冻害。
二、乘车安全
阴极保护维护过程中,大量时间花在路上,乘车要遵守交通规则,系好安全带。严禁酒后驾车,**速行车。乘车人中,职位较高或岁数较大的人对行车安全负责。
三、用电安全
设备上的开关关闭并不代表不带电。需要进行设备内部检查设备 一定要断掉总电源,并做到挂牌锁,标签上应往用断电原因、断电人姓名以及联系大式。只有挂锁人才有资格去掉挂锁,开启电源。维修电气设备人员要有相应的资质。
四、防爆区工作安全
在站场内部工作时,要遵守站场防火防爆的规定,打开接线箱前,要确认没有可燃气体或已经断电。
五、**动物的伤害
在野外工作时,要注意蛇、虫、马蜂等动物的侵害,高山密林中要配备通信设备,长途跋涉时要携带充足的食物和水,必要时,双车出行。
六、高压线下方及沟下作业
野外测量管地电位时,尤其当上方有高压线时,要先放置参比电极,后与管道连接。先测量交流电压,再读直流电位。尽量采用单手操作。沟下作业时,要预留逃生通道,防止洪水浸泡。
Safety protection in cathodic protection system maintenance
Human life is only one time. Before all work is started, safety shall be assessed and risks shall be identified. Never start work in an unsafe environment, and really think twice before acting.
1、 Personal protection
Wear appropriate labor protection clothing and glasses, and do a good job in personal safety protection. Work in a relaxed manner to ensure food and environmental hygiene in the camp. Prevent high temperature and heatstroke in summer and cold and freezing damage in winter.
2、 Ride safety
During cathodic protection maintenance, a lot of time is spent on the road. When riding, you should abide by traffic rules and fasten your seat belt. Drunk driving and speeding are strictly prohibited. Among the passengers, the person with the highest position or the oldest age is responsible for driving safety.
3、 Electricity safety
The switch on the equipment is closed, which does not mean that it is not electrified. For the equipment requiring internal inspection, the main power supply must be cut off, and the tag must be locked. The reason for the power failure, the name of the person who cut off the power and the contact form should be on the tag. Only the padlock is qualified to remove the padlock and turn on the power. The maintenance personnel of electrical equipment shall have corresponding qualifications.
4、 Work safety in explosion-proof area
When working in the station, observe the regulations on fire and explosion prevention in the station. Before opening the junction box, make sure there is no combustible gas or the power has been cut off.
5、 Damage to wildlife
When working in the field, pay attention to the harm of snakes, insects, wasps and other animals. Communication equipment should be equipped in high mountains and dense forests. Sufficient food and water should be taken with you when you travel long distances. If necessary, you can travel in two cars.
6、 Operation under high voltage line and trench
When measuring the pipe ground potential in the field, especially when there is a high-voltage line above, the reference electrode should be placed first and then connected to the pipe. Measure the AC voltage before reading the DC potential. Try to use one hand operation. When working under the ditch, an escape route shall be reserved to prevent flooding.
词条
词条说明
铝阳极大多数用于海水环境金属结构或原油储罐内底的阴极保护,不能用于氯离子含量低的土壤环境。其电极电位为 -1.05V CSE。温度**49°,电容量随温度递减,在咸水中,电流容量可能会降低到一半。铝阳极直接固定在被保护结构上,*填料。较高的电化学性能,单位重量的阳极材料发电量大,约为锌阳极的3倍,镁阳极的2倍。在海水及含氯离子的其它介质中,性能良好,发出电流的自调节能力强。铝合金牺牲阳极适用于海
智能测试桩简介智能测试桩由标志桩、桩座和保护电位检测仪组成,其特征在于标志桩设为圆柱形或矩形,其底部周长大于上部周长,桩座为圆形或矩形,桩座内设有保护电位监测仪,在桩座周侧设有保护电位监测仪的两个接线柱,其中一个接监测探头,另一个接被监测管线上的监测点,标志桩中心设有接收发射较,并稍露出标志桩**部,其较与保护电位监测仪内的GPRS通讯模块电路相接,在保护电位监测仪上设有GPRS通讯模块的接口,直接
(1)通电电位中含有IR降。 将阴极保护电源开启24h,沿线测量的管地电位为管道的通电电位,通电电位读数中含有土壤中的电压降,即IR降。当参比电极远离管道或靠近阳极地床时,电压读数中含有更大的IR降。将参比电极放置在管道一侧测量的管地电位要比将参比电极放在管道正上方测量的管地电位更负。如果管道有杂散电流排放,管道正上方的电位会更负。通电电位受多方面因素影响,只能用来评估阴极保护系统的工作状况,不能
阴极保护系统电缆的区分 Differentiation of cathodic protection system cables
阴极保护系统电缆的区分恒电位仪面板有四根电缆线,正极连接阳极地床,负极连接被保护结构,零位接阴连接被保护结构,参比电极连接埋地参比电极,可以通过测量两两电缆之间的电阻把阴极电缆线和零位接阴线与其他电缆线区分开。剩余的两根电缆线,可以用万用表黑表笔连接其中一根线,红表笔连接零位接阴线, 如果读数为-0.6Vᴄse左右, 则黑表笔连接的是参比电极, 剩余的一根电缆线为阳极电缆线,根据阳极材料以及填包方
公司名: 焦作市虹泰防腐材料有限公司
联系人: 张晓莎
电 话:
手 机: 18339709689
微 信: 18339709689
地 址: 河南焦作武陟县武陟县大虹桥乡大虹桥村
邮 编: